Specifications
Backplane and Enclosures
System Specifications A-5
Table A-2. ftServer V 200 and V 400 Systems Specifications (Page 1 of 2)
Power
Output wattage A-side power: 1300 W (AC)
B-side power: 900 W (AC)
Nominal input voltage; frequency 200–240 VAC; 50-60 Hz
Physical Dimensions
Height 17.75 in. (45 cm) (10U)
Width 19 in. (48.26 cm)
Depth 30 in. (76.2 cm)
Weight 310 lb. (136 kg)
Environmental Requirements
Operating temperature 41
F to 95F (5C to 35C)
For every 800 ft. (243.8m) above 2000 ft. (609.6m), lower the
maximum operating temperature (95F/35C) by 1.8F (1C)
Storage temperature -38
F to 140F (-40C to 60C)
Operating altitude 0 ft. to 10000 ft. (0m to 3048m)
Maximum rate of temperature
change during operation
53.6F/hr. (12C/hr.)
Relative humidity during operation 10% to 80% (noncondensing)
Relative humidity during storage 5% to 95% (noncondensing)
Heat dissipation 7500 BTUs per hour
CPU Enclosure Features
Processors Two or four Intel
®
Xeon
™
processors in each CPU enclosure
Memory Utilizes four or eight dual-inline memory module slots in each
CPU enclosure
Up to 12 gigabytes (GB) logical memory
I/O Enclosure Features
Ports One embedded 10/100/1000-Mbps Ethernet port on each core
I/O enclosure
Two AC power connectors