Specifications

Planning for Communications and Data Cables
4-4 Stratus ftServer V 100, V 200, and V 400 Systems: Site Planning Guide (R543)
RSN console server to host
AA-E96600 RSN dialup console server (if present) to modem
Hydra communications cables for U760 PICMG 2.16 adapter in network
I/O enclosure
Configurations That Include U772 and U773 Switches
For ftServer systems that include U772 Ethernet and U773 fibre channel switches, you
will need to consider the following cables:
Ethernet cables (AW-B38029):
One cable to connect one U772 Ethernet switch to RSN console server
Two cables to connect two U772 Ethernet switches to two embedded Ethernet
ports (one on each core I/O enclosure)
Two cables to connect the two U772 Ethernet switches to two U773 fibre
channel switches
If ftScalable storage array is present, one cable to connect one U772 Ethernet
switch to the PC console (which you must supply) for Web management of
ftScalable Storage array
If ftScalable storage array is present, four cables to connect two U772 Ethernet
switches to two ftScalable Storage RAID controller trays
Two Ethernet cables which you must supply to connect two UPS units to two
U772 Ethernet switches
If a network I/O enclosure is present, two Ethernet cables to connect port 1 of a
U575V Ethernet adapter in slot 0 of each core I/O enclosure to the network I/O
enclosure Ethernet switches
Serial cables to connect:
System console to the ftServer system
RSN console server to an ftServer system
AA-E96600 RSN dialup console server (if present) to modem
Fibre Channel cables (AW-B90000-020) to connect Fibre Channel PCI adapters,
U773 fibre channel switches, and ftScalable Storage arrays (if present)
Hydra cables for U760 PICMG 2.16 adapters in network I/O enclosure
For All Configurations
You will need to consider the cables for PCI adapters in your system. See Table 4-6 for