[Technical Parameters]
List 1:
Input Voltage
DC12V/1A
Standby Current
<55mA
Alarming Current
<450mA
Wireless Frequency
315/433MHz, PT2262/EV1527, 4.7MΩ
GSM Frequency
850/900/ 1800/ 1900MHz
Back-up Battery
NI-HI AAA*6 DC7.2V
Siren Volume
110dB
List 2:
Defense Zone
Arm
Home Arm
Type
Alarm
Information
Siren
Zone 1
effective
invalid
real-time
Door alarm
yes
Zone 2
effective
invalid
real-time
Hall alarm
yes
Zone 3
effective
effective
real-time
Window alarm
yes
Zone 4
effective
effective
real-time
Balcony alarm
yes
Zone 5
effective
effective
24 hours
Fire alarm
yes
Zone 6
effective
effective
24 hours
Gas alarm
yes
Emergency button
effective
effective
24 hours
Emergency alarm
no
Zone 7-99
effective
invalid
real-time
Emergency alarm
yes
Wired defense zone(93-99)
effective
invalid
real-time
Emergency alarm
yes
Operation Password
8888
Remote control
On
Remote Control Password
1234
Siren