MOBILE CALL GSM Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it.
Contents Alarm Number Setting Function Introduction Delete Phone Number Alarm Host Diagram SMS Number Setting Door Sensor Delete SMS Number Wireless PIR Detector SMS Notification for Arm/Disarm Functions Settings Defense Zone Programming Initialization Home Arm Defense Zone Setting Enter Settings Voice Recording Exit Settings Arm/ Disarm Siren Sound Setting Factory Reset Emergency Help Siren Setting Coding of Remote Controller Arm/ Disarm Voice Prompt Delete Remote Controller Voice Pr
Components List Care and Maintenance [Function Instruction] 1. 7 wired and 99 wireless defense zones; 2. LCD screen with time clock display; 3. Voice prompt for all operations; 4. 3 groups of timely arm and disarm; 5. Can store 6 phone numbers: when alarming, system will make alarm call to these numbers automatically; 6. Can store 3 SMS numbers: when alarming, system will send alarming SMS automatically; 7. 10-second automatic message recording; 8.
concrete wall or fire door, etc.
1 LB- Negative of speaker (black cable) 2 LB+ Positive of speaker (red cable) 3 GND Ground 4 Z1 5 GND Wired sensor 1: support both NO and NC 6 Zone 2 Wired sensor 2: support both NO and NC 7 Zone 3 Wired sensor 3: support both NO and NC 8 GND 9 Zone 4 Wired sensor 4: support both NO and NC 10 Zone 5 Wired sensor 5: support both NO and NC Ground GND 11 GND 12 Zone 6 GND Wired sensor 6: support both NO and NC 13 Zone 7 Wired sensor 7: support both NO and NC 14 SP- Negat
3. Please pay attention to the siren connection. Do not mix the two cables together when connecting. Otherwise, it will damage the transistor in the main panel. LCD display: [Door Sensor] Door sensors are used for detecting the status of open and close of windows and doors. It will detect it and send the signal to main panel. Tear apart the double-side adhesive tape on the magnet and the transmitter. Then adhere them to the appropriate position.
Magnet should be near to the side of transmitter with indicator. The two should align with each other and the distance should not exceed 10mm. Please plug out the antenna for better signal. If the low-power indicator is on, please change the battery. [Wireless PIR Detector] PIR detectors are used to detect the movement within a certain range. the Fix adjustment bracket on the wall with the provided screws and attach the detector to the bracket.
Choose the most suitable installation place and angle according to actual situation and taking the following installation diagram as reference to ensure the detection effect is best. Please do not fix it under direct sunlight or other strong lights and also keep it away from places with frequent strong air stream. If the low-power indicator is on, please change the battery. [Function Settings] 1.
LCD display: 3. Exit Settings Press [*] and [#] buttons, the main unit emits a long beep and exits settings. The [SET] indicator goes out and the system returns to disarm state. Operating method: 【*】【#】 4. Factory Reset In disarm status, use keypad to input [95175308246] and press [#] to confirm, all the LED indicators will be on for 2 seconds and you will hear a long beep. The main unit gets all its settings cleared and restores to its factory settings successfully.
The remote controller can’t control the main unit after it’s deleted. In setup state, use keypad to input [21], then input the remote controller number [1-8], and then press [#] to confirm. The main unit emits a long beep and the [Signal] indicator flickers once. You will hear a voice prompt “delete completed”. Operating method: [21] [A] [#] A indicates: 1~8 remote controllers number. 7. Coding of Defense Zone Wireless detectors have to be coded to the main unit in order to trigger it alarm.
1) Change Operation Password Operation password is the password used to disarm or remote control. In setup status, use keypad to input [30], then input the 4-digit new password, and then press [#] to confirm. The main unit will make a long beep and you will hear a voice prompt “setting completed”.
digits [EE] of the minute, the two digits [FF] of the second, and finally enter [#] to confirm. You will hear a long beep and a voice prompt “setting completed”.
Operating method: [XX][AA][BB][#] XX indicates: the address code 36, 37, 38 of the timely disarming AA indicates: the hour of the setting time BB indicates: the minute of the setting time For example: set the arm time as 55’ 7am Operating method: [33][22][45][#] LCD display: 3) Timing Control In setup status, use keypad to input [39], then input the number indicating turning on timely arm/ disarm [1/0], and then input [#] to confirm. You will hear a long beep and a voice prompt “setting completed”.
LCD display: 13. Wireless Siren Coding Encryption Only the panel with built-in transmitter has this function. The signal used to code with the wireless siren is sent from the internal transmitter of the main panel. The signal codes of this product from our company are the same. If you and your neighbor both are using this product, the alarm signal from your neighbor may cause your siren sound. So it is recommended to encrypt the wireless siren to avoid the interference.
In setup state, input the command: 45 + [XX] + # XX indicates: the delay time of alarm; XX= 01-99: 1 sec to 99 sec Note: The setting is effective only when a zone is set as Alarm Delay Zone. Note: Before the system enters arm or alarm status it will emit a "Di" sound per second. 16. Alarm Number Setting In setup state, input [51] ~ [56], then input the voice alarm-receiving number (mobile number or telephone number), and then press [#] to confirm.
18. SMS Receiving Number Setting SMS Receiving number means when system is alarming, it will only send SMS to this mobile number. You can set maximum 3 SMS numbers. In setup state, input [57] ~ [59], then input the SMS receiving number, and then press [#] button to confirm. The main unit will make a beep, the [Signal] indicator will flicker once and you will hear “setting completed”, which indicate setup successfully.
keyboard operation. 21. Defense Zone Programming If you want to change the alarm attribute of defense zone, such as turn off the siren when system alarms, you can do it by defense zone programming. In setup state, first input [60], then the defense zone number [01~99], then input defense zone type [1~4], then input defense zone location number [1~8], and then select siren on/off [0/1], at last press [#] to confirm. You will hear the main unit emit a long beep and a voice prompt “setting completed”.
defense zone number [01~99], then choose [Home Arm], and then choose whether alarm [0/1] button, and finally press [#] to confirm. The main unit will make a long beep and a voice prompt “setting completed”.
24. Arm/ Disarm Siren Sound Setting After you activate this function, when you arm the system, the external siren will sound one short beep; and when you disarm it, there will be two short beeps. In setting status, use keypad to input [75], then [0/1] and finally press [#] to confirm; voice prompts: setting completed, please enter instruction”.
confirm; voice prompts: setting completed, please enter instruction. Operating method:【83】【A】【#】 A indicates: [1]: activate voice prompt for arm/ disarm (factory default) [0]: deactivate voice prompt for arm/ disarm 27. Voice Prompt for All Settings For above settings, you could hear the voice prompt such as “setting completed, please enter instruction”, “delete completed”. You can deactivate the voice if you do not need them.
Users can use remote controller to set system as Out Arm, Home Arm, Emergency Alarm, Real-time Disarm and etc. Out Arm: Press button Disarm: Press button Home Arm: Press button Emergency Alarm: Press button, system will alarm at once. 3.
After the setting, the host makes a "Di" sound, ARM LED is on and you will receive a SMS: System armed. 5. Disarm It means to stop the alarm when the main unit sounds the alarm or make the alarm system in the state of non-warning. After disarming, even if you trigger the detector, the main unit would not sound alarm (excluding 24-hour defense areas). Use keypad to input system password, then press [#] button. [Out Home] or [At Home] lights will be off. It means disarm setting successful.
If you answer the call, you will hear the pre-record voice. You can set system via your telephone or mobile phone keypad. If you hang-up directly without answering the call, the system will call each preset number for 3 times circularly. Press [*]: Read the alarm information. Press [1]: Main unit stops alarming and Arm; it stops calling users. Press [2]: Main unit stops alarming and Disarm; it stops calling users.
In disarm status, you can use the main unit to make any call just like a land-line telephone. Dial telephone number on keypad, press [ ] button, the main unit will make a beep and the [Signal] indicator will be flashing. After the call, press [ ] button again, the main unit will be in disarm status. 10. Alarming Record Checking In disarm state, input [*0#], then the main unit will make a long beep and enters the state of alarm record checking.
NO9 Zone: 19 Time: 11-06-25 11:45 (It indicates the first record: wireless zone 19 alarm time) 11. GSM Signal Checking Before installing the main unit, you should check the signal of the installing place in order to ensure the unit can perform well. In setup state, input [81] #, the main unit will make a long beep and display 00+XX (XX indicates the intensity of the signal). And the intensity should be within the range of 07-31; if it’s less than 07, you should change place.
[Technical Parameters] List 1: Input Voltage DC12V/1A Standby Current <55mA Alarming Current <450mA Wireless Frequency 315/433MHz, PT2262/EV1527, 4.7MΩ GSM Frequency 850/900/ 1800/ 1900MHz Back-up Battery NI-HI AAA*6 Siren Volume 110dB DC7.
Siren sound time 180 sec. Home Appliance Optional [Components List] Main panel 1 pc, Remote controller 2 pcs, Siren 1 pc, PIR sensor 1 pc, Door sensor 1 pc, Power adapter 1 pc, User manual 1 pc. [Care and Maintenance] The alarm system has excellent design and uses advanced technologies. It shall be used with care. The following suggestions are required to maintain your obligations under the warranty terms, and for prolonging the service life of the system.
Keep the alarm system dry. Rain, humidity and various fluids or moisture all will corrupt the electronic circuit. Do not use or place the alarm system in dirty locations, otherwise the electronic elements will be damaged. Do no place the system in excessively hot locations. High temperature will shorten the service life of electronic equipment, damage batteries, deform or even melt some plastic parts. Do not place the system in excessively cold locations.
other people remote control the system illegally. Since the alarm system is continuously in operation or standby mode, the supply adaptor of the control panel shall be connected to a safe and reliable socket. Do not place the system near your bedroom or office table, because the siren will make high-loudness sound in the case of alarm, which may adversely affect your rest or work. If the alarm system will not be used for a long time, please disconnect the system from the power supply.
Optional sensors/detectors are packed separately. You can choose according to your specific requirements.
Operation Function Description Remarks Commands [Program Password] + Enter settings Default password: 8888 [#] [*] + [#] Exit settings [20]+[1~8] + [#] Max 8 remote controllers [21]+[1~8] + [#] Coding of Remote Controller Delete Remote Controller [23] +[01~99] + [#] Coding of Defense Zones Defense Zones Number: [24] +[01~99] + [#] Delete Defense Zones 01~99 Defense Zones Number: 01~99 [30]+[password] + [#] Change Operation Default: 1234 Program Default: 8888 Password [31]+[password] +
[AA]: hour [BB]: minute [39] + [0/1] + [#] Timing Control: turn on/ 0: OFF 1: ON Wireless Transmission Control Wireless Siren Coding Encryption 0: OFF 1: ON Out Arm Delay Time Default: 60seconds off the function of timely arm/disarm [41] + [0/1] + [#] [42] + [01~99] + [#] [44] + [01~99] + [#] Siren coding number: 01~99 Setting [45] + [01~99] + [#] Alarm Delay Time Setting Default: no delay [51]~[56] Alarm Number Setting 6 groups of alarming user + Phone number + [#] number Delete Pho
[1]SOS Alarm; [2] Fire Alarm; [3]Gas Leak Alarm; [4]Door Alarm; [5]Hall Alarm; [6]Window Alarm; [7]Balcony Alarm; [8]Boundary Alarm D: Siren ON/OFF [0] OFF, [1] ON [61] + [01~12] + [0/1] + [#] Home Arm Defense Zone Setting Defense zone number: 01~12; [0] Home arm but not alarm; [1] Home arm and alarm [70] + [1] + [#] Voice Recording 10 seconds [75] + [0/1] + [#] Siren Setting [0]: off (default); [1]: on [76] + [0/1] + [#] Siren Setting in [0]: off (default); [1]: on “Emergency Help” mo
[Dial number] +[ telephone System Dialing Function ] [95175308246] + [#] Factory Reset Use with caution [operation password] + Arm by SMS Default [1] [operation password] + password: 1234 Disarm by SMS [2] [operation password] + [3] operation Default operation password: 1234 Alarm Record Checking by SMS 34 Default operation password: 1234