Specifications

41
Model
CPS
SC1.5KTL
CPS
SC2KTL
CPS
SC2.8KTL
CPS
SC4KTL
CPS
SC4KTL-O
DC insulation resistance
2
> 5MΩ
Output (AC)
Nominal AC power 1500W 2000W 2800W 4000W 4000W
Max. AC power (in 10 minutes) 1650W 2200W 3000W 4400W 4400W
Nominal AC current 6.6 A 8.7 A 12.2 A 17.4 A 17.4 A
Max. AC current 7.9 A 10.5 A 14.3 A 20 A 20 A
O/P current distortion (THD i) < 3%
Power Factor > 0.99
Operational voltage range
3
(F/W Setting)
190 ~ 256V
Disconnection time of
excess operational voltage
range
0.2 sec.
for Germany
(DE)
Operational frequency
range
4
(F/W Setting)
47.55 ~ 50.15 Hz
2
The DC resistance requirement for positive or negative terminal to chassis ground
3
Regulation voltage range is 184~264.5 V
AC
according to VDE0126-1-1
4
Regulation frequency range is 47.5~50.2Hz according to VDE0126-1-1.