6. Inverter Status
This inverter is designed to be user-friendly; therefore, the status of the Inverter can be easily understood
by reading the information shown on the front panel display. All possible messages are shown in the following
table.
Display information
Operating
conditions
In English In German In Italian Description
Normal Working
Status
Power off
- - -
PV inverter is totally shutdown, V
PV
<70V
Standby Standby Standby Standby 70V< Input voltage <120V
Initialization & waiting Waiting Warten Attendere..
Input voltage range 120~150V during
start-up. After PV voltage is higher than 120V,
inverter is waiting for feeding to grid
Check grid Checking xxxS Netzprüfung xxxS Verifica… xxxS
When PV voltage> 150V, inverter is checking
feeding conditions
Feeding grid, MPPT Normal Normalbetrieb Stato Normale
Inverter is feeding power. After 10 seconds of
this display, LCD will show wattage.