User Manual
10
HEARTH REQUIREMENTS
12mm (minimum)
3.7a Hearth requirements
Domestic
Summary table
Chilli Billie, no enclosure 12mm superimposed, stove fixed to hearth
(Stove anchor plate available)
Chilli Billie in enclosure Hearth is integral to enclosure, stove fixed to
enclosure & enclosure fixed to floor
(Stove anchor plate available)
Hearth in front of stove 225mm
Hearth both sides of stove 150mm
These recommendations apply in non domestic structure with a fixed shall and firm, stable
permanent floor e.g. shepherds hut.
Do not place any soft furnishing within 1150mm of the stoves
If the structure that the Chilli Billie is being installed in has a non-permanent shell or floor
we recommend a hearth even with the enclosure. This is to provide a stable level base of
support for the stove and flue system. This base should be placed directly onto the ground
rather than on top of a superficial floor surface and should be completely level. This is to
avoid any possibility of disturbance to flue joints/stove by foot traffic.
3.7b Hearth requirements
Non
domestic
Summary table
Chilli Billie no enclosure 12mm superimposed, placed on flat level
stable ground, stove fixed to hearth
(Stove anchor plate available)
Chilli Billie in enclosure 12mm superimposed, placed on flat level
stable ground, stove fixed to enclosure &
enclosure fixed to heath (stove anchor plate
available)
Hearth in front of stove 225mm
Hearth both sides 150mm
These recommendations apply in structures with no fixed shell or permanent floor eg yurt,
tepee. Do not place soft furnishings within 1150 mm of the stoves.
3.6 installation-Hearth (cont)
3.7b Hearth
non-domestic/other structures
3.7 Hearth (cont)