ChilliP-A5-Manual-2020-Download

Sweeping
3.p Chimney and Access for Sweeping
Chimney / Flueway
Must comply with all current building regulations.
We recommend that all masonry chimneys are lined.
Minimum Flue Height 4.5 metres
Stove models
with no smoke
control kit fitted
Lined with 150mm diameter class 1 liner with 125mm stove pipe + adaptor
Stove models
with smoke
control kit fitted
Lined with 150mm diameter class 1 liner where possible, where not,
125mm flue is permitted
Provision must be made for sweeping access and for the removal of soot and debris.
Lined chimney
If the correct super flexible rods are used. The debris will fall into the fire box from where
it can be removed. All stoves including cooker models can be swept through unless a rear
horizontal adaptor is used (in this case additional sweeping provision will be needed).
Unlined chimney
If the chimney is unlined the cooker models cannot be swept through the stoves (due to size
of brushes) so additional sweeping provision will need to be made.
A flue way must not be shared with other appliances
A flue way must be gas tight and free of tar deposits
New chimney: A new chimney of factory made insulated flue system must comply with Building
Regulations. Consult a chimney specialist for advice on suitable flue systems for solid fuel.