ChilliP-A5-Manual-2020-Download

Single walled flue pipe must be at least 3 times its diameter away from any
combustibles eg. a timber beam. This may be reduced if adequate protection is
provided to prevent heat transfer (see section 3, Heat shielding). N.B be aware that it
is possible, particularly in older properties for timber beams to enter the inside of the
chimney cavity so it must be inspected.
3.o The Flue Pipe (single wall)
3.n Direct Air Kit (non-room sealed only)
All of our models have the option of a factory fitted direct air kit. There are a large
number of criterias that need to be assessed prior to fitting and commissioning. Please
refer to the HETAS Guidelines and Commissions Procedure (HETAS TN-0020).
27
www.chillipenguin.co.uk
270mm Direct Air Inlet dia 62mm,
Horizontal or Vertical option
Flexipipe ext.dia 72mm
A
750mm
Dimension A
The Short Penguin
The Chubby 5
The Woody
The Hungry Penguin
The Fat Penguin
The High and Mighty
The Penguin 8
The Chubby 8
The Eighty Ate “88”
The Eighty Ate “88” Shorty
50mm
195mm
70mm
50mm
50mm
270mm
50mm
275mm
270mm
50mm
Spigot can be turned 90° to face
downward with center of spigot in
line with rear of stove.