ChilliP-A5-Manual-2020-Download

The temperature at the base of a stove will aect the type of hearth required, see
“hearth requirements”. If a constructional hearth is required but is not possible,
then a base heat shield can be fitted underneath the stove. This reduces the hearth
temperatures and allow the stoves to be installed onto a superimposed (12mm) hearth.
Record on the guarantee page whether a base heat shield has been fitted.
3.h Base Heat Shield
To fit: Slide in at the base of the stove prior to
installation. It needs to slide in from the rear.
The edge with the cut-out should slide in first,
resting at the front of the stove. The folded
legs of the heat shield will sit on the tabs for
the leveling screws, (these are small square
tabs with a hole in the centre).
22
Diagrams illustrating the minimum distances to non combustible walls. (i.e. stone/brick)
3.g Non Combustible Walls
Side
Rear
Model Rear
NB. Flue pipe safe distances can be greater than the appliance, depending on type
MINIMUM DISTANCES TO NON COMBUSTIBLE WALLS
All Models 50mm
Sides
100mm
Rear wall thickness needs to be at least 200mm thick.
These are minimum distances.
Above
150mm