ChilliP-A5-Manual-2020-Download
Make sure the floor can take the weight of the stove, the flue, the hearth and any
decorative surround.
3.e Floors
A hearth is made up of 2 layers: a constructional hearth (base concrete layer) and a
superimposed hearth (top decorative layer). In some circumstances a superimposed
hearth is acceptable on its own. All of our stoves require a constructional hearth unless
the stoves are either on a plinth or have a base heat shield fitted. (The Penguin 8 has
not currently been tested for use with a base heat shield but it can go on a plinth).
3.d Hearth
All models without
base heat shield or plinth
Constructional total depth (incl.
superimposed) 125mm
All models on plinth Superimposed 12mm (minimum)
All models (except Penguin 8) with
base heat shield
Superimposed 12mm (minimum)
In front of the stove 225mm (minimum)
Both sides of the stove 150mm (minimum)
NB. Do not place any soft furnishings within 1150mm of the stove
20
150mm
Minimum distance from stove to edge of superimposed hearth
225mm150mm
All freestanding stoves require a superimposed hearth of at least 850x850mm square