5.l Trouble Shooting
Possible cause Remedial Action
1. Fuelisdamp
2.Firehasbeensmothered
3.Insucientair
1. Ensure fuel is dry
2. Load smaller amounts of fuel at a time – be patient!
3. Air boost disc has been closed before the fire has been
established (see Making a Fire, section 4)
CANNOTGETFUELTOSTAYALIGHT
SMOKEENTERSROOM
1. Blockedueway
2.Damagedchimney
3.Siteandlocationof
chimney
1. Let the fire go out then drop the throat plate or throat plate
brick down and check for blockages. Sweep chimney
2. Get chimney inspected
3. If flue is clear and stove installed correctly and problem
persists – seek professional advice
GLASSBLACKENS
(SMALLLOCALISEDAREASWHEREWOODHADFALLENAGAINSTTHEGLASSISNORMAL,
THISWILLBURNOFFASTHEFIREGETSHOTTER)
Aircontrolscloseddown
toosoonbeforere
established
Leave air controls open longer
Somediscolourationoftheglassisnormalafterseveralres,
inthecoolerareasoftheglassdoor:nearthefuelretainer
andthecorners.Thiswillburnoffinahotfireorcanbe
removedwhenstoveiscoldwithglasscleaner/dampcloth
dippedinwoodash(see Keeping Stove Glass Clear, section 5)
CHIMNEY FIRE
Byfollowingtheinstructionsinthismanual,includingregularcleaningofthestoveand
uesystemyoushouldavoidthepossibilityofachimneyre.Intheunlikelyeventthat
oneoccurs,raisethealarmtoletothersinthehouseknow,calltheFireService,iftime
andsafetyallowsclosethestoveaircontrols,andexitthebuilding.
CATALYTICCONVERTERHASSTOPPEDGLOWING
Cat.iscontaminated Couldbecontaminatedwithyashordepositsfromincorrect
fuel-hoovercatalyticconverters(see Maintenance, section 5).
Cat.isexhausted Iftheydonotgloworangeonahighametheywillneedtobe
replaced(see Maintenance, section 5).