ChilliP-A5-Eco-Manual-2020-Download
Problem
5.l Trouble Shooting
Possible cause Remedial Action
1. Fuelisdamp
2.Firehasbeensmothered
3.Insucientair
1. Ensure fuel is dry
2. Load smaller amounts of fuel at a time – be patient!
3. Air boost disc has been closed before the fire has been
established (see Making a Fire, section 4)
CANNOTGETFUELTOSTAYALIGHT
SMOKEENTERSROOM
1. Blockedueway
2.Damagedchimney
3.Siteandlocationof
chimney
1. Let the fire go out then drop the throat plate or throat plate
brick down and check for blockages. Sweep chimney
2. Get chimney inspected
3. If flue is clear and stove installed correctly and problem
persists – seek professional advice
GLASSBLACKENS
(SMALLLOCALISEDAREASWHEREWOODHADFALLENAGAINSTTHEGLASSISNORMAL,
THISWILLBURNOFFASTHEFIREGETSHOTTER)
Aircontrolscloseddown
toosoonbeforere
established
Leave air controls open longer
Somediscolourationoftheglassisnormalafterseveralres,
inthecoolerareasoftheglassdoor:nearthefuelretainer
andthecorners.Thiswillburnoffinahotfireorcanbe
removedwhenstoveiscoldwithglasscleaner/dampcloth
dippedinwoodash(see Keeping Stove Glass Clear, section 5)
CHIMNEY FIRE
Byfollowingtheinstructionsinthismanual,includingregularcleaningofthestoveand
uesystemyoushouldavoidthepossibilityofachimneyre.Intheunlikelyeventthat
oneoccurs,raisethealarmtoletothersinthehouseknow,calltheFireService,iftime
andsafetyallowsclosethestoveaircontrols,andexitthebuilding.
CATALYTICCONVERTERHASSTOPPEDGLOWING
Cat.iscontaminated Couldbecontaminatedwithyashordepositsfromincorrect
fuel-hoovercatalyticconverters(see Maintenance, section 5).
Cat.isexhausted Iftheydonotgloworangeonahighametheywillneedtobe
replaced(see Maintenance, section 5).
Page 56 of 60