WRONG FUEL
Onlyburndry,seasonedwoodintheWoodyCat.IntheMultiFuelstoves,dry,seasoned
woodorsmokelessfuelcanbeused. DONOTtreatyourstoveasanincineratorfor
gereralrubbish.DONOTuseanyliquidfuels.
CHIMNEY FIRE
Intheeventofachimneyre,closeallstovedoorsandairvents.Evacuatethehouse
andphonethereservice.
PRE-LIGHTING CHECKS
• Checkthatthedoorclosescorrectlyandtheropesealsandglassareintact
• Checkthatthethroatplatebrickispositionedcorrectly
• Checkthatalllabelsandpackaginghavebeenremoved(includingfromtheuesystem)
• Checkthatanyaccesspointsintheueareclosedoe.g.sweepingaccess
4.e Simple Guide to your First Fire
Werecommendthegoldilocksandthethreebearsmethod;smallre,mediumre,hotre.
read this manual and a warnings carefuy
TheA,B&Coflightingyour1ststovereare:
A=aircontrolB=burndrywoodC=curepaintcarefully
prepare a sma kindling fire
• scrunchupnewspaperorrelighters,placekindlingoverthetop,lightthere,closethestovedoor
• openallaircontrols
• ventilateroom
• maintainthisSMALLFIREfor15minutes
• thiswarmsupthestovecomponentsgentlytopreventsthepaintsfrombeing“shocked”
medium fire
• addafewsplitlogs
• maintainmediumreforonehour
• closeairboostdiscandprimaryair(lefthandknob)whenburningwell
• aimtoraisethesurfacetempto450°F/230°C
• controlonsecondaryaircontrol(righthandknob)
hot fire
• addadditionalwood
• adjustcontrolstoallowadditionalairowtoachieveahotre
• aimtoachieve600°F/315°C
• maintainhotreforonehour