Diagramsillustratingtheminimumdistancestocombustiblewallsi.ewood/plasterboard
3.f Combustible Walls
MINIMUMDISTANCESTOCOMBUSTIBLEWALLS
Side
Rear
Model Rear Both Sides Above
HungryPenguinEco
withinsulatedpipe
250mm 550mm 450mm
ShortPenguinEco 350mm 500mm 450mm
ShortPenguinEco
withinsulatedpipe
200mm 500mm 450mm
HungryPenguinEco 350mm 550mm 450mm
HighandMightyEco
withinsulatedpipe
250mm 250mm 450mm
FatPenguinEco 350mm 250mm 450mm
FatPenguinEco
withinsulatedpipe
250mm 250mm 450mm
HighandMightyEco 350mm 250mm 450mm
TheWoody(Cat)
withinsulatedpipe
150mm 400mm 550mm
Chubby5Eco 350mm 250mm 450mm
Chubby5Eco
withinsulatedpipe
200mm 250mm 450mm
TheWoody(Cat) 350mm 400mm 550mm
TheWoody(Multifuel)
withinsulatedpipe
150mm 400mm 550mm
TheWoody(Multifuel) 350mm 400mm 550mm
Rear distances to combustibles using a non-insulated flue pipe include safe distances
required by building regulations. See heat shielding section if reduced distances are
required.