ChilliP-A5-Eco-Manual-2020-Download
Page 12 of 60
MULTI-FUEL
NominalOutput
Total Energy Eciency %
CO content @13% O2
Dust Concentration @ 13% O2
NOx mg/m
3
Cx Hy mg/m
3
FlueGasg/s
MeanFluegastemp.°C
SmokeControl/DEFRAExemptionTestingcomplete
SeasonalEciency
SuitableForSmokeControlZones(FactoryFitted)
Max.Loglengthxaveragediameter
Max.Fuelload
FlueCollarDiameter
FlueSizeRequired
TopExit
RearExit
HearthTypeNoBaseHeatShield/Plinth
HearthWithBaseHeatShield/Plinth
Chimneydraughtrequired
Construction
Weight
Tested to EN13240:2001-2004 / BS 3841-2:1994
For distances to combustibles / non-combustibles see section 3
WOOD
4.7kW
81.2%
0.10%
33mg/m
3
135mg/m
3
96mg/m
3
4.8g/s
224°C
Yes
71.2%
Yes
270mmx100mm
2.5kg
127mm
Min125mm
Standard
Fituecollartorear
Constructional
12mm
12Pa
Weldedsteel
104kg
SMOKELESS FUEL
4.8kW
86.6%
0.06%
12mg/m
3
119mg/m
3
37mg/m
3
2.9g/s
247°C
Yes
76.6%
Yes
3kg
127mm
Min125mm
Standard
Fituecollartorear
Constructional
12mm
12Pa
Weldedsteel
104kg
The Tech Details
Spares are available through your local Chilli stockist or
our online shop. There are diagrams online to help you
identify the correct parts and advice about how to fit:
www.chillipenguin.co.uk/FAQ/looking-after-your-penguin