Specifications

15
1-1.5K/7K/9K/12K
Above 100mm
Above 100mm
Above 70mm
Above 100mm
Above 350mm
Above 195mm
Above 120mm
Above 30mm
7
A
C
D
B
E
6
5
Above 500mm
VI. Installation instructions
Installation & Maintenance Manual
Be careful!
Do not let drain hose run up.
Connect the pipeline at two sides, and
insulation should be carried out respectively.
Fitting pipe of pipeline may be led out
from back side, right side, lower side,
left side or left rear side.
Left rear
Left
Right
Back side
Rear
Downwards
Front side
Aerated plastics with a thickness of
8mm for heat insulation
If the pipeline is to be installed upon a
wall equipped with steel sheet
(galvanized sheet) or metal net, plank
with a thickness of 20mm should be
positioned between the wall and the
pipeline, or the pipeline should be
wrapped with 7~8 layers of insulating
plastic tape.
Enclosed attachments
Installation attachments
Qty
1
2
3
4
5
6
7
Mounting plate
Tapping screw ST4*25
Expansion plug
Expansion bolt
Battery for remote controller
Remote controller
Connecting cable
1
5
2
2
1
A
B
C
D
E
F
G
Connecting pipe
Bandage
Tensioning rope
Masonry nail
Drain hose
Putty
Sealing oil
5
1
Unit
2
1
5
1
3
1
1
Pcs
Pcs
Qty
Unit
Pcs
Box
Bottle
Piece
Pieces
Pieces
Piece
Piece
Pieces
Piece
Pcs
Piece
1. Installation diagram
H
UA
LING