Service manual
37 
Trouble
Is the power 
applied to the unit? 
Check power supply mains or 
interconnection wires
Is the power normal? check 
the voltage between L&N of 
terminal block 
Check the wiring of indoor and 
outdoor 
Press the power ON/OFF button 
of wire control or remote control
YES
YES
NO
NO
Does the beeper 
beep?
Is the display all 
off?
Check the connector on display 
PCB connected to control PCB 
Check the display PCB itself
Is the unit display 
normal?
Does outdoor unit run?
Does the 
compressor run 
normally?
Check the failure code 
according to the failure 
table
Normal 
Check the 
compressor ,wires 
and it’ s 
capacitor.
YES
YES
YES
YES
YES
YES
NO
NO
NO
Does the control 
ok? 
Does the control 
PCB ok? 
Control failure
Control PCB failure
NO
NO
YES
NO
 Trouble shooting 
NO
Does the indoor 
unit run?