Service manual
34 
Turn off power 
supply once, and 
turn it on again.
Does 
compressor 
continue to 
operate?
Start to operate indoor 
unit in cooling 
operation at airflow 
level “ LOW” ,wait 
three minutes..
Does indoor 
fan operate?
Fan motor 
operates 
normally.
Is it possible to detect AC 
220V between 
pin(high/middle/low) and 
pin(common) of motor 
connector . 
Replace indoor 
fan motor.
Replace main 
P.C. board.
Replace 
bearing.
YES
YES
YES
NO
NO
NO
Turn off indoor unit and rotate 
cross-flow fan by hand when the 
unit is on standby.Is it possible to 
rotate cross-flow fan by hand 
properly?
Only indoor fan motor does not operate.
Is capacitor of indoor fan ok?
YES
NO
YES
Replace 
capacitor
NO
<Primary check>
(1) Is it possible to detect the power supply voltage (200-240V) between L and N on the terminal 
block?
(2) Does the indoor fan motor operate in cooling operation?