INSTALLATION INSTRUCTIONS XSM1U XTM1U FUSION EXTRA LARGE HEIGHT ADJUST FLAT PANEL MOUNTS XSM1U/XTM1U
XSM1U/XTM1U Installation Instructions DISCLAIMER Milestone AV Technologies, and its affiliated corporations and subsidiaries (collectively "Milestone"), intend to make this manual accurate and complete. However, Milestone makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product.
Installation Instructions XSM1U/XTM1U DIMENSIONS 42.00 1066.8 XSM1U 42.75 1085.9 2.25 57.2 3.75 95.3 31.50 800.0 1.47 37.4 0.49 TYP. 12.5 24.00 609.6 MINIMUM UPRIGHT SPACING 4.75 120.7 11.81 300.0 8.00 203.2 6.00 152.4 16.00 406.4 1.82 46.2 23.62 600.0 7.00 177.8 17.00 431.8 1.48 TYP. 37.5 26.25 666.8 0.34 8.6 3.00 76.2 RAILS CAN BE SLID LEFT OR RIGHT FOR OFFSET 0.34 8.7 1.83 46.6 1. 2. 3. MAXIMUM MOUNTING PATTERN IS 38.
XSM1U/XTM1U Installation Instructions DIMENSIONS--continued 42.00 1066.8 XTM1U 42.75 1085.9 0.49 TYP. 12.5 2.5 63.1 24.00 609.6 MINIMUM WALL UPRIGHT SPACING 11.81 300.0 4.75 120.7 12° 24.50 622.3 8.5 216.9 1.82 46.2 8.50 215.9 1.48 TYP. 37.5 16.00 406.4 6.00 152.4 7.00 177.8 17.00 431.8 0.34 8.6 23.62 600.0 24.07 611.3 31.00 787.5 3.00 76.2 2.05 52.0 3.05 77.5 0.34 8.7 RAILS CAN BE SLID LEFT OR RIGHT FOR OFFSET 1. 2. 3. 4 MAXIMUM MOUNTING PATTERN IS 36.
Installation Instructions XSM1U/XTM1U LEGEND Tighten Fastener Pencil Mark Apretar elemento de fijación Marcar con lápiz Befestigungsteil festziehen Stiftmarkierung Apertar fixador Marcar com lápis Serrare il fissaggio Segno a matita Bevestiging vastdraaien Potloodmerkteken Serrez les fixations Marquage au crayon Loosen Fastener Drill Hole Aflojar elemento de fijación Perforar Befestigungsteil lösen Bohrloch Desapertar fixador Fazer furo Allentare il fissaggio Praticare un foro Beve
XSM1U/XTM1U Installation Instructions TOOLS REQUIRED FOR INSTALLATION 1/8" (included) 5/32" (included) 7/32" (5.5mm) Wood Stud 3/8" (9.
Installation Instructions XSM1U/XTM1U INSTALLATION The XSM1U/XTM1U mounts are designed to be mounted to: Center of screen • a bare concrete wall with a minimum thickness of 8" (203mm); • a bare 8" x 8" x 16" (203mm x 203mm x 406mm) concrete block wall; or • wood studs spaced 24" or 32" (610mm or 813mm) on center with a maximum drywall covering of 5/8". The XTM1U has brackets which allow the TV to be tilted. The XSM1U has static brackets which keep the TV in an upright position. 8" (203.
XSM1U/XTM1U Installation Instructions Installing to a Concrete Wall CAUTION: MINIMUM HORIZONTAL DISTANCE BETWEEN WALL BRACKETS IS 24" (610mm). Do not place mounting brackets closer together than 24" (610mm). 13. Use two 5/16 x 2-1/2" flanged lag bolts (J) and two 5/16" slotted washers (L) to attach the mount to the wall through the lower mounting holes. (See Figure 3) 14. Slide rails to approximate center of screen location. Locking Rails (Optional) 1.
Installation Instructions XSM1U/XTM1U Attaching Interface Brackets to Screen Switching Interface Brackets (Optional) 1. If an installation situation makes adjusting the location of interface brackets necessary, there are several options. Align the center of the bracket (V and W or X and Y) with center of screen. (See Figure 5) NOTE: The diamond-shape holes in the bracket correspond to the center of the mount. (G) (A-F) (H) 1.
XSM1U/XTM1U 3. Installation Instructions If necessary, the tilt interface bracket knobs may be switched to allow the interface brackets (X and Y) to be reversed. (See Figure 8) NOTE: NEVER place both interface brackets (V and W or X a. Remove display from mount. b. Remove interface brackets from display. c. Hold the right interface bracket horizontally, tightly gripping it so that spacers do not move. d. Remove the knob and screw. e.
Installation Instructions XSM1U/XTM1U IMPORTANT ! : (XSM1U Only) Completely extend bottom of interface brackets (by pulling downward) to set interface brackets in SERVICE position before hanging on top rail. (See Figure 11) 2. Hang screen onto the top rail of the mount (Z).
XSM1U/XTM1U Installation Instructions OPTIONAL: Adding Pull Knob (XSM1U Only) Roll/Height Adjustment of Wall Brackets 1. If necessary due to height of tall screen, add pull knob (R) to bottom of interface brackets (V and W) to allow easier accessibility for adjustment purposes. (See Figure 13) NOTE: The height adjust wall brackets allow adjustment of Adjust length of pull knob so it is not visible below screen. (See Figure 13) 1. Turn to right (tighten) to raise side of screen. (See Figure 15) 2.
Installation Instructions XSM1U/XTM1U Tilt (XTM1U Only) The interface brackets (X and Y) allow from -5° to 12° tilt, and can be locked at 0°, 6° and 12°. 1. Loosen the interface bracket knob. 2. Adjust tilt as required. (See Figure 16) 3. The tilt may be locked at 0°, 6° or 12° using one 1/4-20 x 1" round head carriage bolt (S) and one 1/4-20 hex nut (T) per interface bracket. (See Figure 16) 4. Tighten interface bracket knob as necessary.
XSM1U/XTM1U Installation Instructions Backwards Angle Compensation (XSM1U Only) The XSM1U may be slightly adjusted to help compensate for the forward tilt of a heavy screen. NOTE: The interface brackets (V and W) ship in the 0° tilt position. (See Figure 17) 1. With interface brackets in CLOSED position (See Figure 11), remove two fasteners holding tilt compensation in place on each interface bracket (V and W). (See Figure 17) 2. Adjust interface bracket for -1° or -2° back tilt, as required.
Installation Instructions XSM1U/XTM1U Locking Screen Interface Brackets (Optional) Locking Mount (Optional) 1. 1. Lock screen interface brackets onto mount rails using one 3/8-16 x 3/4" set screw (P) on each interface bracket. (See Figure 18) Add padlock (not included) to interface bracket to complete security. (See Figure 19) NOTE: The padlock maximum shackle diameter is 5/16" (7.9 mm). 1 (P) x 2 Padlock shackle maximum diameter: - 5/16" (7.
XSM1U/XTM1U Installation Instructions USA/International Europe Chief, a products division of Milestone AV Technologies 8800-002635 Rev03 2016 Milestone AV Technologies www.chiefmfg.com 01/16 Asia Pacific A P F A P F A 6436 City West Parkway, Eden Prairie, MN 55344 800.582.6480 / 952.225.6000 877.894.6918 / 952.894.6918 Franklinstraat 14, 6003 DK Weert, Netherlands +31 (0) 495 580 852 +31 (0) 495 580 845 Office No.