INSTALLATION INSTRUCTIONS WITH TS118 WITH TS218 THINSTALL™ IN-WALL ENCLOSURE Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description TA502
TA502 Installation Instructions DISCLAIMER Milestone AV Technologies, and its affiliated corporations and subsidiaries (collectively, "Milestone"), intend to make this manual accurate and complete. However, Milestone makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product.
Installation Instructions TA502 DIMENSIONS GROUNDING 18.85 478.8 GROUNDING TRIM NOT SHOWN NOTES: ELECTRICAL KNOCK OUTS: 1. • SINGLE GANG RACO 590. STEEL CITY CY 1/2, OR SIMILAR STYLE ELECTRICAL BOX. • 1" AND 2" TRADE PIPE CONDUIT. 2. PRODUCT WORKS WITH TS118 AND TS218.
TA502 Installation Instructions TOOLS REQUIRED FOR INSTALLATION 3/16" PARTS Grounding screw and washer installed at factory Earthing symbol IEC 60417 No. 5019 affixed adjacent to grounding terminal.
Installation Instructions TA502 INSTALLATION TA502 CUTOUT AREA WARNING: IMPROPER INSTALLATION CAN RESULT DEATH OR SERIOUS PERSONAL INJURY! This accessory should be installed by qualified personnel. Site Preparation Locate and Prepare Mounting Site 1. Identify a suitable wall location for the in-wall enclosure. IMPORTANT ! : The TA502 is designed for in-wall installation between two wood studs, 16" on center.
TA502 Installation Instructions NOTE: Ensure screws are far enough from block end to prevent interference with framing screws installed in InWall Enclosure Installation section. 3. If necessary, cut rectangular hole in horizontal framing to accommodate the PAC-GB1 Listed electrical box accessory (not included). 4. Attach horizontal framing to each support block with two #10 x 2-1/2" countersunk wood screws (not provided). (See Figure 2) 7 (D) x 4 In-Wall Enclosure Installation 1.
Installation Instructions TA502 (TS118SU install) 1/4" 3 2 Grounding Lug Locations (N) Figure 6 TS118/218SU Installation TS118SU IMPORTANT ! : The TA502 was designed specifically for the TS118SU and TS218SU wall mounts. Do not attempt to install any other wall mounts with the TA502! 1. Use four 5/16-18 x 1/2" button head cap screws (M) to attach attach bracket (P) to the TA502 (A). (See Figure 7) 1 Figure 8 (TS218SU install) 1/4" (M) x 4 3 (P) 2 Figure 7 2. 3.
TA502 Installation Instructions (G) x 4 (TS118SU install) (TS118/218TU mount not shown for clarity) 5 3 TS118SU (N) 4 Figure 10 1 (K) x 16 (TS218SU install) 5 Figure 12 Cable Management 4 (N) x 2 TS218SU Figure 11 6. Complete TS118/218SU installation according to corresponding installation instructions. Trim Kit (Optional) 1. Remove paper covering adhesive and affix three tape squares (K) to inside lower flange of each trim piece (G). (See Figure 12) 2. Orient trim pieces (G).
Installation Instructions TA502 9
TA502 10 Installation Instructions
Installation Instructions TA502 11
TA502 Installation Instructions USA/International Chief Manufacturing, a products division of Milestone AV Technologies Europe Asia Pacific 8800-002233 Rev00 2012 Milestone AV Technologies, a Duchossois Group Company www.chiefmfg.com 12/12 A P F A P F A 6436 City West Parkway, Eden Prairie, MN 55344 800.582.6480 / 952.225.6000 877.894.6918 / 952.894.6918 Franklinstraat 14, 6003 DK Weert, Netherlands +31 (0) 495 580 852 +31 (0) 495 580 845 Office No.