Specifications
RSME Installation Instructions
8
1c
Ø 2.5mm
(Ø 3/32”)
45mm
(1-3/4”)
Wood Stud Installation
NOTE: CPA adapter must be removed prior to
installing RSME to wood studs. See Section 1a
for details.
1. Carefully determine required mounting location.
IMPORTANT ! : This will require knowing the lens
to screen distance. See projector specifications for
details on determining this distance.
WARNING: IMPROPER INSTALLATION CAN
RESULT IN SERIOUS PERSONAL INJURY OR
DAMAGE TO EQUIPMENT! Structural members
MUST be capable of supporting five times the
combined weight of all equipment being mounted.
IMPORTANT ! : The RSME mounts are designed to
be mounted to double 2" x 4" wood stud cross bracing
(1-1/2" on center) between two ceiling joists; with a
maximum drywall covering of 5/8".
2. Using the RSME as a guide, mark four mounting
hole locations with a pencil or similar tool. Hole
locations must be centered on 2" x 4" cross braces.
3. Drill four 3/32" (2.5mm) dia. pilot holes to a depth of
1-3/4" (45mm) deep.
4. Align four mounting holes in RSME with four pilot
holes.
IMPORTANT ! : Make sure mount is properly
oriented towards target before securing to
structure.
5. Secure RSME to structure using four #10 flat
washers and four #10 x 3" Phillips head wood
screws (not included).
x 4
x 4
5
3
1
2
4
(A)
x 4