Specifications
PIWRF SERIES Installation Instructions
6
WARNING: ELECTRICAL SHOCK HAZARD! CUTTING
OR DRILLING INTO ELECTRICAL WIRES OR CABLES
CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY!
ALWAYS make certain area behind mounting surfaces is free
of electrical wires and cables before cutting, drilling, or
installing fasteners.
WARNING: EXPLOSION AND FIRE HAZARD! CUTTING
OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH
OR SERIOUS PERSONAL INJURY! ALWAYS make certain
area behind mounting surfaces is free of gas, water, waste, or
any other plumbing before cutting, drilling, or installing
fasteners.
5. Cut drywall on outside edge of lines and remove.
6. Assemble upper and lower mounting rails (B) to mount (A)
in slots that correspond to the desired lateral shift offset
identified during Step 3 above using four flanged nuts (K)
assembled to mount (A). (See Figure 3) and (See Figure 4)
Figure 4
7. Install J-box(s) [not included] and route all in-wall cables
and wiring to mount enclosure keeping in mind the lateral
shift offset determined during Step 3 above. (See Figure 3)
WARNING: IMPROPER INSTALLATION CAN LEAD TO
MOUNT FALLING CAUSING SEVERE PERSONAL INJURY
OR DAMAGE TO EQUIPMENT! Wiring of equipment must
be performed by properly trained and certified persons
following all applicable codes.
8. Slide mount (A) enclosure into opening in wall.
(See Figure 5)
Figure 5
9. Place spacers (C) provided between wall and upper and
lower mounting rails (B) if required. (See Figure 6)
Figure 6
10. Secure mount to studs using four flat washers (F2) and four
lag screws (F1). (See Figure 7)
(B) x 2
(K) x 4
6
6
(A) x1
(A) x 1
8
(B) x 2
(C) x 4
8