User Guide

7
PAC525/526 Site Preparation
Using a level, draw a horizontal line at lower edge of
install site.
A - STUD ATTACHMENT - create exploratory hole to
confirm edge of stud/studs.
B - DRYWALL ATTACHMENT - mark horizontal cut
locations ensuring a minimum 1/2ā€ distance from
each stud.
7
12
Align on lower edge drawn line (A) and horizontal
marking for inside stud location (B).Use enclosed
template or housing as a template, drawing line
around top and sides of housing.
8
A
A
A
B
B
Cut along outside
edge of line using
utility knife.
Remove drywall.
NOTE:
Cutting past corners
weakens the cleats’
ability to hold securely.
9
PAC525/526 Box Preparation
10
Once wall opening is completed, check stud depth. If 3.5ā€ or greater, proceed to step 11. If less than 3.5ā€ deep, modify depth
of box as follows before proceeding: CAUTION:
Injury may occur on sharp edges. Carefully discard the removable tabs.
A - Remove box flange by removing screws.
B - Snap off removable tabs
at perforations provided.
C - Reinstall box flange. Reattach screws.
11
PAC525/526 Box Installation
Feed attached conduit through cut-out and insert box
into opening in wall. Tighten component connections.
13
B B
Installation Instructions
PAC525/526
Use four #6 screws (F)
and nuts (G) to assemble
the switch box from either
inside or outside the
PAC525 or PAC526.
Mark the four corners.
CAUTION:
Avoid sharp edges.
Remove knock-outs in box as predetermined in
step 5.
Loosely attach components and conduit (cut to length)
to box to ease fitting into wall opening.