Product Manual

Explanation of Tank Drain Decal
Read and understand
the instruction manual
WARNING ! Drain the tank
WARNING !
Condensation could cause
rust resulting in reduced
wall thickness and risk of
explosion.
Drain the tank daily
Visually inspect the tank
every year
Drain locator
(general location)
Visual inspection log
(annual entries made by
operator)
Air Tank Inspection
The factory recommends that all
air tanks be inspected at scheduled inter
vals. Refer to Fig. 3-5 Recommended
Air Tank Inspection Intervals
relative information.
Refer to federal, state or provincial,
or local codes for mandatory air tank
Fig. 3-5 Recommended Air Tank Inspection Intervals
Tank
Capacity
Horizontal
or
Vertical
Minimum Allowable
Wall Thickness
Visually
Inspect
Head Shell
30 Gal. Horizontal .094 .106 Yearly
60 Gal. Horizontal .109 .135 Yearly
60 Gal. Vertical .109 .111 Yearly
80 Gal. Horizontal .109 .135 Yearly
80 Gal. Vertical .131 .133 Yearly
120 Gal. Horizontal .131 .162 Yearly
120 Gal. Vertical .163 .199 Yearly
200 Gal. Horizontal .163 .199 Yearly
240 Gal. Horizontal .163 .199 Yearly
-
for
maintenance information.
Hydrostatically
Inspect
10 Years
10 Years
10 Years
10 Years
10 Years
10 Years
10 Years
10 Years
10 Years
-
-