Technical Specifications

8
800.843.7584 www.cherneind.com
Simply thread into test tee
and inate (for maximum
sealing performance, apply
thread seal tape to the
threads before use).
Designed for stack testing of drain, waste, and vent
plumbing systems, Clean-Seal
®
plugs thread into a
standard test tee. The bladder is inated and then water is
introduced into the pipe. Upon test completion, deate the
bladder; water travels down the pipe, eliminating test water
backsplash.
Features:
Works in both plastic and cast-iron test tees
Natural rubber body provides a leak-free seal
High-impact ABS threads for maximum durability
Removable/replaceable tire ination valve tting
Clean-Seal
®
& Clean-Seal
®
2 Plugs
Clean-Seal
Part
Number
Nominal
Size
Maximum
Back Pressure
Ination Pressure
Product
Weight
Deated
Length
Deated
Diameter
Ination
Thread
271508
1.5"
(40 mm)
13 psi
(0,9 bar)
30 ft.
(9.1 M)
30 psi
(2,1 bar)
.15 lbs
(0.07 kg)
4.75"
(121 mm)
1.5"
(38 mm)
1/8"
271705
2"
(50 mm)
13 psi
(0,9 bar)
30 ft.
(9.1 M)
35 psi
(2,4 bar)
.3 lbs
(0.14 kg)
5.81"
(150 mm)
2.38"
(60 mm)
1/8"
271713
3"
(75 mm)
13 psi
(0,9 bar)
30 ft.
(9.1 M)
35 psi
(2,4 bar)
.8 lbs
(0.36 kg)
7.38"
(188 mm)
3.5"
(89 mm)
1/4"
271721
4"
(100 mm)
13 psi
(0,9 bar)
30 ft.
(9.1 M)
35 psi
(2,4 bar)
1.3 lbs
(0.59 kg)
8.5"
(215 mm)
4.5"
(115 mm)
1/4"
271758
6"
(150 mm)
13 psi
(0,9 bar)
30 ft.
(9.1 M)
25 psi
(1,7 bar)
3.5 lbs
(1.59 kg)
11"
(280 mm)
6.63"
(168 mm)
1/4"
Inated (test) Deated (test release)
Clean-Seal
®
Application
The Clean-Seal
®
2’s new patent-pending design adds the
ability to plug, ll and drain a DWV system from any PVC,
ABS or cast iron tee. Cherne has added Clean-Seal 2 to
their broad offering of DWV test products. Trusted by the
trade as the best in the business, Clean-Seal 2 offers the
same reliable features as the original Clean-Seal with the
ability to test the DWV system with either air or water. No
longer ll a DWV system from the stack or use other
complicated multi-piece products.
Features:
Patent pending design
Plug, ll and drain from same cleanout tee
M
ulti-lobe gasket allows sealing of all tees including cast iron
Hand-tighten in place, no tools required
Rubber cap protects hose connection when not in use
Check-valve allows removal of hose after lling system
and keeps DWV water from back-lling into potable lines
Clean-Seal 2
Part
Number
Nominal
Size
Maximum
Back Pressure
Ination Pressure
Product
Weight
Deated
Length
Deated
Diameter
Ination
Thread
271828
2”
(50 mm)
13 psi
(0,9 bar)
30 ft.
(9.1 M)
35 psi
(2,4 bar)
.35 lbs
(0.16 kg)
5.5"
(140 mm)
3.5"
(89 mm)
1/4"
271838
3”
(75 mm)
13 psi
(0,9 bar)
30 ft.
(9.1 M)
35 psi
(2,4 bar)
.85 lbs
(0.39 kg)
5.5"
(140 mm)
5"
(127 mm)
1/4"
271848
4”
(100 mm)
13 psi
(0,9 bar)
30 ft.
(9.1 M)
35 psi
(2,4 bar)
1.4 lbs
(0.64 kg)
6.75"
(171 mm)
5.75"
(146 mm)
1/4"
New
Product!
TECHNICAL DATA TOOLS & ACCESSORIES TESTING EQUIPMENT DEFLECTION GAUGES MECHANICAL PLUGS PNEUMATIC PLUGS