Technical Specifications
8
800.843.7584 www.cherneind.com
™
Simply thread into test tee
and inate (for maximum
sealing performance, apply
thread seal tape to the
threads before use).
Designed for stack testing of drain, waste, and vent
plumbing systems, Clean-Seal
®
plugs thread into a
standard test tee. The bladder is inated and then water is
introduced into the pipe. Upon test completion, deate the
bladder; water travels down the pipe, eliminating test water
backsplash.
Features:
•
Works in both plastic and cast-iron test tees
•
Natural rubber body provides a leak-free seal
•
High-impact ABS threads for maximum durability
•
Removable/replaceable tire ination valve tting
Clean-Seal
®
& Clean-Seal
®
2 Plugs
Clean-Seal
Part
Number
Nominal
Size
Maximum
Back Pressure
Ination Pressure
Product
Weight
Deated
Length
Deated
Diameter
Ination
Thread
271508
1.5"
(40 mm)
13 psi
(0,9 bar)
30 ft.
(9.1 M)
30 psi
(2,1 bar)
.15 lbs
(0.07 kg)
4.75"
(121 mm)
1.5"
(38 mm)
1/8"
271705
2"
(50 mm)
13 psi
(0,9 bar)
30 ft.
(9.1 M)
35 psi
(2,4 bar)
.3 lbs
(0.14 kg)
5.81"
(150 mm)
2.38"
(60 mm)
1/8"
271713
3"
(75 mm)
13 psi
(0,9 bar)
30 ft.
(9.1 M)
35 psi
(2,4 bar)
.8 lbs
(0.36 kg)
7.38"
(188 mm)
3.5"
(89 mm)
1/4"
271721
4"
(100 mm)
13 psi
(0,9 bar)
30 ft.
(9.1 M)
35 psi
(2,4 bar)
1.3 lbs
(0.59 kg)
8.5"
(215 mm)
4.5"
(115 mm)
1/4"
271758
6"
(150 mm)
13 psi
(0,9 bar)
30 ft.
(9.1 M)
25 psi
(1,7 bar)
3.5 lbs
(1.59 kg)
11"
(280 mm)
6.63"
(168 mm)
1/4"
Inated (test) Deated (test release)
Clean-Seal
®
Application
The Clean-Seal
®
2’s new patent-pending design adds the
ability to plug, ll and drain a DWV system from any PVC,
ABS or cast iron tee. Cherne has added Clean-Seal 2 to
their broad offering of DWV test products. Trusted by the
trade as the best in the business, Clean-Seal 2 offers the
same reliable features as the original Clean-Seal with the
ability to test the DWV system with either air or water. No
longer ll a DWV system from the stack or use other
complicated multi-piece products.
Features:
•
Patent pending design
•
Plug, ll and drain from same cleanout tee
•
M
ulti-lobe gasket allows sealing of all tees including cast iron
•
Hand-tighten in place, no tools required
•
Rubber cap protects hose connection when not in use
•
Check-valve allows removal of hose after lling system
and keeps DWV water from back-lling into potable lines
Clean-Seal 2
Part
Number
Nominal
Size
Maximum
Back Pressure
Ination Pressure
Product
Weight
Deated
Length
Deated
Diameter
Ination
Thread
271828
2”
(50 mm)
13 psi
(0,9 bar)
30 ft.
(9.1 M)
35 psi
(2,4 bar)
.35 lbs
(0.16 kg)
5.5"
(140 mm)
3.5"
(89 mm)
1/4"
271838
3”
(75 mm)
13 psi
(0,9 bar)
30 ft.
(9.1 M)
35 psi
(2,4 bar)
.85 lbs
(0.39 kg)
5.5"
(140 mm)
5"
(127 mm)
1/4"
271848
4”
(100 mm)
13 psi
(0,9 bar)
30 ft.
(9.1 M)
35 psi
(2,4 bar)
1.4 lbs
(0.64 kg)
6.75"
(171 mm)
5.75"
(146 mm)
1/4"
New
Product!
TECHNICAL DATA TOOLS & ACCESSORIES TESTING EQUIPMENT DEFLECTION GAUGES MECHANICAL PLUGS PNEUMATIC PLUGS