VT-HMI-156-TEL VT-HMI-156-TEL User’s Manual Chengdu Vantron Technology, Ltd.
VT-HMI-156-TEL Contents 1 FOREWORD ............................................................................................................................................................. 2 1.1 COPYRIGHT NOTICE.............................................................................................................................................................. 2 1.2 NOTES ...........................................................................................................................
VT-HMI-156-TEL Revision History No. Version Description Date 1 V1.
VT-HMI-156-TEL 1 Foreword 1.1 Copyright Notice While all information contained herein have been carefully checked to assure its accuracy in technical details and printing, Vantron assumes no responsibility resulting from any error or features of this manual, or from improper uses of this manual or the software. Please contact our technical department for relevant operation solutions if there is any problem that cannot be solved according to this manual.
VT-HMI-156-TEL 1.3 Statement It is recommended to read and comply with this manual before operating 15.6-inch Computer which provides important guidance and helps decreasing the danger of injury, electric shock, fire, or any damage to the device. 1.4 Disclaimer Vantron assumes no legal liability of accidents resulting from failure of conforming to the safety instructions. 1.
VT-HMI-156-TEL 1.7 Precautions Pay attention to the product labels/safety instructions printed on silk screens. Do not try repairing this product unless declared in this manual. Keep away from heat source, such as heater, heat dissipater, or engine casing. Do not insert other items into the slot (if any) of this device. Keep the ventilation slot ventilated for cooling. System fault may arise if other items are inserted into this device.
VT-HMI-156-TEL 1.8 Safety Instructions for Power Cables and Accessories Proper power source only Start only with power source that satisfies voltage label and the voltage necessary according to this manual. Please contact technical support personnel of Vantron for any uncertainty about the requirements of necessary power source.
VT-HMI-156-TEL 1.9 Product Usage Environment: 15.6-inch Computer could be mounted into a metal casing station and then mounted on the wall or other place. The highest installation height is less than 2 meters. Pic1. 15.6-inch Computer Pic2. VESA Pic3. Front metal Pic4. Mount assembly Installation diagram is as follows: Step1. Mount the 15.6-inch Computer with the VESA; Step2. Mount the assembly into front metal. Step3. Installation the whole assembly on the wall or other place. Pic5. Front view P ic6.
VT-HMI-156-TEL 2 Overview 2.1 Introduction Thank you for choosing Vantron. It is our commitment to provide our valued customers with the embedded devices equipped with the state-of-the-art technology and the best product services. The HMIenables the interaction between operators/users and applications, connects industrial control products such as wireless, transducer, battery inside, storage, etc.
VT-HMI-156-TEL 2.2 Ordering Information 15.6’ TFT LCD, 1920*1080 16:9, RK3399, Qaud-Core2.0GHz, VT-HMI-156-TEL USB OTG Type C,USB2.0+USB3.0 HOST, A udio J ack,Speaker a nd MIC,WIFI/BT4.
VT-HMI-156-TEL 3 VT-HMI-156-TELHardware Instructions 3.
VT-HMI-156-TEL 3.2 Specifications Function VT-HMI-156-TEL CPU RockchipRK3399 Qaud-Core Cotex-A72 2.0GHz+Daul-core-A53 1.4GHz Display 15.6"LCD,1920x1080 Brightness :250cd/㎡ Touch CAP TP, support 10 points touch, and 3.0mm cover glass. System Memory DDR32GB Standard Storage 16GB eMMC Flash Camera Front 5MP, 25fps LocalNetwork WLAN 802.11 b/g/n/ac& Bluetooth 4.2 External Antenna 1xUSB Type C (5V 1.4A) IOs Host USB2.0(5V 0.5A )+Host USB3.0(Type-A,5V 0.8A), USB2.
VT-HMI-156-TEL 3.3 Interface Instructions 3.3.1 Front View Front Camera Reset button 3.3.
VT-HMI-156-TEL 3.4 Dimension Outline dimension: 395*250*35mm Metal Cover 3.5 Interface Description 3.5.1 USBOTG (Type C) One hand, with a standard type-c USB port, customer can connect the HMI to the host machine for example a PC, then manage it like all other android devices. On the other hand, if the HMI is connected through a USB OTG cable, it can be a host machine to operate the device that is connected to it. 3.5.2 USB Host The HMI owns a USB 2.0 and a USB3.
VT-HMI-156-TEL 3.
VT-HMI-156-TEL 4 Software Instructions 4.1 Brief Introduction VT-HMI-156-TEL has been pre-loaded with Android image, so that the system can run Android tool to update the system image, please reference to SW-UM.
VT-HMI-156-TEL 5 Tips Waste Disposal It is recommended to disassemble the device before abandoning it in conformity with local regulations. Please ensure that the abandoned batteries are disposed according to local regulations on waste disposal. Do not throw batteries into fire (explosive) or put in common waste canister. Products or product packages with the sign of “explosive” should not be disposed like household waste but delivered to specialized electrical& electronic waste recycling/disposal center.
VT-HMI-156-TEL safety tips for operation environment. Notice Considering that reasonable efforts have been made to assure accuracy of this manual, Vantron assumes no responsibility of possible missing contents and information, errors in contents, citations, examples, and source programs. Vantron reserves the right to make necessary changes to this manual without prior notice. No part of this manual may be reprinted or publicly released in forms of photocopy, tape, broadcast, e-document, etc.
VT-HMI-156-TEL RF Exposure Statement This equipment must be installed and operated in accordance with provide instructions and the antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operation in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.
VT-HMI-156-TEL US Office: Vantron Technology, Inc. Address: 440 Boulder Court, Suite 300, Pleasanton, CA 94566 Tel: +1 916-202-7042 Email: sales@vantrontech.com China Office: Chengdu Vantron Technology, Ltd. Address: No.5 GaoPeng Road, Hi-Tech Zone, Chengdu, SiChuan, P.R. China 610045 Tel: 86-28-8512-3930/3931, 8515-7572/6320 Email: sales@vantrontech.com.