User's Manual
8
A. The human body is outside the radar range
Radar scanning range, and adjust the installation
angle.Radar measurement range, in different environments,
the electromagnetic wave reflected area is different, the
scanning area will have small differences.
B. Metal occlusion causes an incorrect output
Overthick office tables and chairs, metal seats.It will
block the electromagnetic wave penetration, causing
misjudgment.
C. Scan angle difference
The radar was not scanned to the trunk position.Cause a
miscarriage of judgment.
D. Radar sensitivity is too low
Radar provides parameter adjustment to increase sensitivity
improvement.
6. Functional details
6.1. Function point description
Function point
Status change time / function explanation
DP1:Someone / nobody
No one arrived, reported within 0.5s
Someone to no one, 1-2 minutes or so
output no state, 0.5s
DP2:Someone is still / someone is active
Static dynamic switch, reported within 0.5
seconds
DP3:Someone is close to the equipment /
Someone moves away from the
device / someone moving without
direction
Output the status once in 2 seconds
DP4:Body motion amplitude parameter 0
– 100
Output the data once in 5 seconds Refer
to (Description of the bulk motion
amplitude parameter output)
DP5:Sensitivity is set in gear 0- 9
In default scenario mode, 10 gear
adjustments are supported