User's Manual
Table Of Contents
- General
- Module introduction
- Hardware description
- Approvals
- CE Approvals (ETSI)
- FCC Approvals
- ATEX Approvals
- Module Pinout
- Hardware Description
- Hardware Diagram
- Interface characteristics
- Absolute Maximum Ratings
- Environmental characteristics
- Recommended operating conditions
- DC Electrical Characteristics
- Digital IO Specifications
- AC Electrical Characteristics
- Physical Dimensions and Footprint
- Physical Dimensions
- Recommended Footprint
- Soldering Temperature Time Profile (for reflow so
- Recommended temperature time profile for lead-fre
- Reliability Test
- Application Precautions
- Safety precautions
- Engineering design and using precautions
- Storage conditions
- Packaging
- Carrier tape
- Reel
- Ordering Information
- Drawing of Product Label
- Disclaimer
- RoHS Declaration
- Data Sheet Status
- Reference Documents
- Contact Information
SZU06A1 Product Manual
SZU06A1 PM(Rev 2.0)
18
11 Reliability Test
To guarantee the environment adaptability of SZU06A1, we have done the the following
measurements.
Table 11-1 Reliability Test of SZU06A1
No
Test items
Test methods
1
Vibration test
Setting the vibration frequency of 50Hz, amplitude of 1.5mm,
and each side of XYZ vibrates for 20 minutes respectively
2
Shock test
The module is dropped from the height of 50cm to hard floor to
carry out the test for 3 times
3
Heat cycle test
Charged operation of module: start temperature of cycle:
25
℃
-->-40
℃
(30 minutes) -->85
℃
(30 minutes), for 5 cycles
between high and low temperature
4
Moisture test
Module operates at the environment of + 60
℃
and 90% RH for
24 hours
5
Low temperature
cold start test
Module will be powered after placed in the environment of
-40
℃
for 1 hour
6
Low temperature
test
Operating in the environment of -40℃ for 3 * 24 hours
7
High temperature
test
Operating in the environment of +85
℃
for 3 * 24 hours