User's Manual

SZU06C1 Product Manual
SZU06C1 PM(Rev 2.0)
12
5.2
Recommended operating conditions
Parameter
Min value
Typical value
Max value
Unit
Environment
Supply voltage
2.1
3.3
3.9
V
RF input power
-
-
10
dbm
RF frequency
2405
2480
MHz
Operating temperature
-40
25
85
-
Relative humidity
-
-
95
%
Table 5-3 Recommended Operating Conditions
6 DC Electrical Characteristics
V 3.3V,T 25 2400MHz 2483.5MHz.
DD OP C
f ℃,
Parameter
Test condition
Symbol
Value
Min.
Type
Max.
Supply Voltage
V
D D
2.1V
3.3V
3.9V
Supply Current
I
VDD
-
-
1000mA
Reset
I
reset
2.1mA
3mA
Hard reset
r e s e t
t
1ms
FLASH
FLSH erase
C
erase
10000
-
-
Flash data retention
t
r e t e n t io n
10years
-
-
Page erase
t
erase
20ms
40ms
I
r e a d
-
-
3mA
Write operation
I
w rite
-
-
3mA
RX Current
Receive enable
I
R X
-
13.7mA
-
TX Current
TX power = 0dBm
I
TX
-
17mA
19mA
TX power = 3dBm
-
23.7mA
24mA
TX power = 8dBm
-
35.5mA
37mA
TX power = 16.5dBm
-
88.4mA
90mA
TX power = 19.5dBm
-
139mA
142mA
Sleep Current
Enter EM2 mode
I
sleep
-
3.0μA
3.2μA
Enter EM3 mode
-
1.7μA
-