6
2. The maximum input parameters stated above shall be considered during installation.
The rules for interconnection of intrinsically safety circuits according EN 60079-11 and
EN 60079-14 have to be taken into account.
3. The maximum service temperature of the communication module when incorporated
into apparatus is -40°C to +80°C. When utilized at this service temperature, a T4
temperature classification is suitable.
4. The communication module shall be installed in an enclosure that provides a minimum
ingress protection of IP20.