SR209/105/107 USER’S GUIDE Chenbro SR209/105/107 Tower&Rackable Server case USER’S GUIDE 1 Revision: 1.
SR209/105/107 USER’S GUIDE Contents 1.1 Introduction 4 5 1.2 Naming Rule 5 1.3 SR10769 Outline 6 1.4 SR107 Front and Rear views 7 1.5 SR107 Side view 8 1.6 SR20969/10569 Outline 9 1.7 SR209 Front and Rear views 10 1.8 SR209 Side view 11 1.9 SR105 Front and Rear views 12 1.10 SR105 Side view 13 1.11 Front Panel Indicators 14 Chapter 1 SR209/SR105/SR107 Server Case Inside Chapter 2 Ultra320 SCSI and Serial ATA Backplanes 2.1 Serial ATA Backplane I.Connectors Layout II.
SR209/105/107 USER’S GUIDE IV. Installing a HDD to hard disk carrier V. Installing a 80mm fan to Hotswap cage VI. Installing a 92mm fan to Non-Hotswap cage VII. Installing HDDs to Non-Hotswap cage VIII. Installing a drive cage into chassis 3 29 30 30 31 31 3.5 Installing the 120mm fan 32 3.6 Installing a 120mm to chassis 33 3.7 Installing the floppy drive, SR107 34 3.8 Installing the CD-ROM drive 35 3.8 Add-on card guide and Retainer, SR107 36 Revision: 1.
SR209/105/107 USER’S GUIDE Chapter 1 SR209/SR105/SR107 Server Case inside Revision: 1.
SR209/105/107 USER’S GUIDE 1.1 Introduction This document will guide you for Chenbro server cases- SR107, SR105, and SR209. They are designed to address the demand of performance and thermal management, and deliver user friendly mechanical design as well as configuration flexibilty on data storage. Additinally, users are able to benefit from their rackable feature. The SR209 and SR105 can be racked by tray, while the SR107 supports rackmount solution of slide rails.
SR209/105/107 USER’S GUIDE 1.3 SR10769 Outline 1 2 3 4 5 6 7 8 No. 1 2 3 4 5 6 7 8 Description 1x3.5”bay 3x5.25” bays Power button RESET button Failure Alarm Mute USB Cover KeyLock Foot Stand Power ON LED HDD activity LED LAN1 activity LED LAN2 activity LED Fan Failure &Overhet LED Revision: 1.
SR209/105/107 USER’S GUIDE 1.4 SR107 Front and Rear Views Side Cover Thumbscrew Optional 5.25” to 3.5” Bracket 5.25” shielding Plates 3.5” FDD Carrier 2 port USB Bracket Optional Hotswap Cage and NonHotswap Cage SR107 Front View Changeable PSU Bracket for PS/2 or N+1 Redundant Optional 120mm Rear Fan Slot bracket with ventilation holes Support Kensington Lock SR107 Rear View 7 Revision: 1.
SR209/105/107 USER’S GUIDE 1.5 SR107 Side View Detachable top cover Optional 120mm T25 fans Add-on card guide and retainer 3 pairs slide rails Optional SCSI and Serial ATA blackplane Optional 92mm fan Non-Hotswap Cage Hotswap Cage for SCSI and Serial ATA backplane Revision: 1.
SR209/105/107 USER’S GUIDE 1.6 SR10569/SR20969 Outline 1 2 3 4 5 6 7 8 No. 1 2 3 4 5 6 7 8 Description 5.25” to 3.5” bracket 3x5.25” bays USB Cover Power ON LED Power button RESET button Alarm Mute HDD activity LED KeyLock Foot Stand LAN1 activity LED LAN2 activity LED Fan Failure &Overhet LED 9 Revision: 1.
SR209/105/107 USER’S GUIDE 1.7 SR209 Front& Rear Views Optional 5.25” to 3.5” Bracket 5.25” shielding Plates 2 port USB Bracket Optional Hotswap Cage and NonHotswap Cage Front ventilation holes SR209 Front View Optional Single PS/2 ATX12V and EPS12V PSU Optional 120mm Rear Fan Slot bracket with ventilation holes Support Kensington Lock SR209 Rear View Revision: 1.
SR209/105/107 USER’S GUIDE 1.8 SR209 Side Views 11 10 1 9 2 3 4 8 7 6 5 80mm fan holder No. 1 2 3 4 5 6 7 8 9 10 11 Description Easy bezel removal design Screws for slide rail installation HDD Cage Optional 92mm fan Add-on card retainer 80mm fan holder Support M/B up to 12”x10.5” Optional screwless holder Optional 120mm rear fan Side cover latch 6 pcs 5.25” slide rails Hotswap Cage optional 92mm fan Non-Hotswap Cage 11 Revision: 1.
SR209/105/107 USER’S GUIDE 1.9 SR105 Front& Rear Views Optional 5.25” to 3.5” Bracket 5.25” shielding Plates 2 port USB Bracket Optional Hotswap Cage and NonHotswap Cage Front ventilation holes SR105 Front View Side cover thumbscrews Optional Single PS/2 or MiniRedundant PSU Optional 120mm Rear Fan Slot bracket with ventilation holes Support Kensington Lock SR105 Rear View Revision: 1.
SR209/105/107 USER’S GUIDE 1.10 SR105 Side View 10 9 1 2 8 3 4 7 6 5 80mm fan holder No. 1 2 3 4 5 6 7 8 9 10 Description Easy bezel removal design Screws for slide rail installation Non-Hotswap HDD Cage Optional 92mm fan Add-on card retainer Support 12” x13” server board Optional screwless holder Optional 120mm rear fan Optional PS/2 or Mini-Redundant 6 pcs 5.25” slide rails Hotswap Cage optional 92mm fan Non-Hotswap Cage 13 Revision: 1.
SR209/105/107 USER’S GUIDE 1.11 Front Panel Indicators No. LED 1 Power 2 HDD Activity 3 LAN1 Activity 4 LAN2 Activity 5 Overheat& Fan failure Status of LED colors Green, Power on Orange, Access IDE HDD Green/Cable connection Blinking green/LAN Activity Red, Fan Failure or HDD overheat No. LEDs 1 Power 2 HDD Activity 3 LAN1 Activity 4 LAN2 Activity 5 Overheat& Fan failure Color of Wires Green/Black RED/Black Orange/Black Yellow/Black Purple/Black, connect to backplane Revision: 1.
SR209/105/107 USER’S GUIDE Chapter 2 Ultra320 SCSI and Serial ATA backplanes 15 Revision: 1.
SR209/105/107 USER’S GUIDE 2.1 Serial ATA Backplane I. Connectors Layout 1 2 10 9 No. 1 2 3 4 5 6 7 8 9 10 Revision: 1.
SR209/105/107 USER’S GUIDE II. HDD Connnectors 1 2 3 4 No. 1 2 3 4 17 Description J1, serial ATA HDD1 connector J2, serial ATA HDD2 connector J3, serial ATA HDD3 connector J4, serial ATA HDD4 connector Revision: 1.
SR209/105/107 USER’S GUIDE III. Jumper Settings S1, Hardware Monitor Switch ON Position No. Function ON OFF 1 FAN1 monitor *Disable Enable 2 FAN2 monitor *Disable Enable 3 Alarm Temperature 50℃ *60℃ 1 2 3 JP1, Front Panel Control Jumper 6 Pin No. Function Pin No. Function 1 System Failure LED+ 2 System Failure LED- 3 GND 4 Alarm Mute Switch+ 5 N/A 6 Alarm Mute Switch- 1 Note: * Default Settings Revision: 1.
SR209/105/107 USER’S GUIDE 2.2 Ultra320 SCSI Backplane, VER:1 I. Connectors& Jumpers Layout 8 10 9 7 1 6 11 12 14 13 2 3 5 No. Description No.
SR209/105/107 USER’S GUIDE II. 80 pins SCA Connectors 1 2 3 4 No. Description No. Description 1 80-pin SCA Connector 1 3 80-pin SCA Connector 3 2 80-pin SCA Connector 2 4 80-pin SCA Connector 4 Revision: 1.
SR209/105/107 USER’S GUIDE III.
SR209/105/107 USER’S GUIDE Alarm Temperature, TEMP_SET 1 6 Temperature P1-P2 SHORT P3-P4 P5-P6 OPEN OPEN * 55℃ OPEN SHORT OPEN 65℃ OPEN OPEN SHORT 45℃ Note: * Default Settings FAN Monitor function, FAN_DIS 1 6 Monitor Mode FAN1(P1-P2) FAN2(P3-P4) *DISABLE SHORT SHORT ENABLE OPEN OPEN Front Panel Control,J3 1 6 Pin No. 1 Description Alarm LED+ 3 N/A 4 N/A 5 MUTE SWITCH 6 MUTE SWITCH Revision: 1.0 Pin No.
SR209/105/107 USER’S GUIDE Chapter 3 Chassis Installation and Assembly 23 Revision: 1.
SR209/105/107 USER’S GUIDE 3.1 Open the front bezel of SR107 A keylock secures the front bezel to protect your system against unauthorized access: (a). Insert the key into the security lock, and turn it clockwise until it points to the unlock icon as figure 3-1. (b).Press two release button on top of front bezel, and the pull it toward yourself (Figure 3-2). (c).Take off the front bezel from chassis body. Figure 3-1 Figure 3-2 3.2 Open the front bezel of SR209/105 1 (a).
SR209/105/107 USER’S GUIDE 3.3 Removing the side cover I. SR209 Side Cover (a).Unlock the keylock(1) on rear 1 panel. (b).Push side cover latch(2) at upper 2 position. (c).Slide the side cover backward, then upward before taking it off from the chassis body. Figure 3-4 Figure 3-5 1 II. SR105 Side Cover (a). Loosen the two thumbscrews(1) at end of side cover on rear panel. (b). Slide the side cover backward, then upward before taking it off from the chassis body. 1 Figure 3-6 25 Revision: 1.
SR209/105/107 USER’S GUIDE III. SR107 Side Cover 1 (a).Remove the front bezel. Refer to the previous section for detailed instructions. (b).Loosen the three thumbscrews(1) of side cover. (c).Slide the side cover toward until it is stopped(2), then upward before taking it off from the chassis body. Figure 3-7 2 Figure 3-8 Revision: 1.
SR209/105/107 USER’S GUIDE 3.4 Installing HDD and HDD Cage I. Before start There are two types of HDD drive cages equipped with SR209, SR105, and SR107, and exist a little bit differences for each product model. These differences are detailed as table below.
SR209/105/107 USER’S GUIDE II. Know hard disk carrier The hard disk carrier is used to hotswap cages of SR209, SR105, and SR107. The assembly parts are detailed as below picture. 7 1 6 2 3 5 4 No. 1 2 3 4 5 6 7 Description Contact spring to chassis HDD Power ON LED HDD activity LED Release button Contact spring to upper carrier Lever Air dam NOTE: User could not fully install four HDDs to the hotswap cage.
SR209/105/107 USER’S GUIDE III. Removing Hotswap or Non-Hotswap Cage (a).Loosen the four thumbscrews, which secure the HDD cage to chassis body. (b).Pull out the HDD cage slightly. (c).Disconnect the SCSI, serial ATA, or power cables. If necessary, the SCSI terminator should be removed. Figure 3-9 (d).Continute to pull out this HDD cage until it is totally out of drive bay. Figure 3-10 IV. Installing a HDD to hard disk carrier (a).Remove the air dam first. (b).
SR209/105/107 USER’S GUIDE V. Installing a 80mm fan to Hotswap cage 1 (a). Insert a 80/T25mm fan into fan holder. Please check if the direction of air flow is correct as Fingurexxx. (b).Let these fan wires be holded by gap(1) of fan holder. (c). Press the ears(2) to let them can hook the mouting holes of Hotswap cage. 2 (d).Align the position pins(3) of fan holder with four key holes(4) on backplane. 4 3 Figure 3-12 (e).
SR209/105/107 USER’S GUIDE VII. Installing HDDs to Non-Hotswap Cage (a).Find the special mounting screws as Figure 3-17 in screw bag. (b).Put the HDD into drive cage, and align with those mounting holes. Figure 3-17 (c).Secure this HDD to drive cage via the four specifc screws with washers. Note: Please have to use washer with screw. Otherwise, that HDD won’t be grounded with chassis. Figure 3-18 VIII. Installing a drive cage into chassis (a).
SR209/105/107 USER’S GUIDE 3.5 Installing the 120mm fan The SR107 is designed to support three 120mm cooling fans with screwless fan holder. There are two fans in middle of chassis, and the other one is mounted on rear panel. (a). Put a 120mm fan into hooks of fan holder (Figure 3-19) (b).Press this 120mm fan to fan holder, and the four positioned pins have to insert into four mounting holes of 120mm fan around the frame. (c).
SR209/105/107 USER’S GUIDE 3.6 Installing a 120mm fan to chassis (a).Install the 120mm fan to fan holder (Figure 3-21). (b).Put the four hooks(1) into specified 120mm fan mouting holes(2) at rear panel or middle panels (Figure 3-23). (c).Slide it toward until you hear a crack sound. 1 Figure 3-21 2 2 Figure 3-23 33 2 Figure 3-22 Revision: 1.
SR209/105/107 USER’S GUIDE 3.7 Installing the floppy drive, SR107 (a). Loosen two screws(1) fastened on side panel of the FDD carrier. 1 Figure 3-24 (b).Insert the hooks, pointed by arrowed in Figure 3-25, into mounting holes of floppy drive. Figure 3-25 (c). Push FDD down into the carrier, and then secure FDD with the two screws you have removed earier. Figure 3-26 (d).Insert the drive carrier with FDD in the drive bay until you hear a crack sound. Figure 3-27 Revision: 1.
SR209/105/107 USER’S GUIDE 3.8 Installing the CD-ROM drive (a).Take out a pair of slide rails from holder(SR209/SR105) or remove them from side panel of drive cage frame in SR107. Figure 3-28 (b).Insert both guide pins, circled in Figurexxx, of slide rail in moutning holes of CD-ROM Drive, and then secure them with screws side by side. (c).Insert the CD-ROM drive in the drive bay until you hear a crack sound. Figure 3-29 Figure 3-30 35 Revision: 1.
SR209/105/107 USER’S GUIDE 3.9 Add-on card guide and Retainer, SR107 I. Detaching Add-on card retainer (a). For convenience of instalaltion or cabling, user could want to remove the add-on card retainer. (b).Push the release button on the top of add-on card holder, and then pull it out. (c). Move it upward slightly, and then detach it totally from chassis body. Figure 3-31 II. Releasing Add-on card retainer (a). Press both releasers, pointed by arrows, and rotate toward righ t. Figure 3-32 (b).