Datasheet
FW2190Liquid
Safety Data Sheet
according to Regulation (EC) No. 1907/2006 (REACH) with its amendment Regulation (EU) 2015/830
4/23/2018
EN (English)
2/7
Name
Product identifier
%
Classification according to
Regulation (EC) No.
1272/2008 [CLP]
3-butoxypropan-2-ol
(CAS-No.) 5131-66-8
(EC-No.) 225-878-4
(EC Index-No.) 603-052-00-8
(REACH-no) 01-2119475527-28
1 - 5
Flam. Liq. 3, H226
Skin Irrit. 2, H315
Eye Irrit. 2, H319
1-methoxy-2-propanol
(CAS-No.) 107-98-2
(EC-No.) 203-539-1
(EC Index-No.) 603-064-00-3
(REACH-no) 01-2119457435-35
1 - 5
Flam. Liq. 3, H226
STOT SE 3, H336
propan-2-ol
(CAS-No.) 67-63-0
(EC-No.) 200-661-7
(EC Index-No.) 603-117-00-0
(REACH-no) 01-2119457558-25
1 - 5
Flam. Liq. 2, H225
Eye Irrit. 2, H319
STOT SE 3, H336
Full text of H-statements: see section 16
SECTION 4: First aid measures
4.1. Description of first aid measures
First-aid measures after inhalation
:
Remove person to fresh air and keep comfortable for breathing.
First-aid measures after skin contact
:
Wash skin with plenty of water.
First-aid measures after eye contact
:
Rinse eyes with water as a precaution.
First-aid measures after ingestion
:
Call a poison center or a doctor if you feel unwell.
4.2. Most important symptoms and effects, both acute and delayed
No additional information available
4.3. Indication of any immediate medical attention and special treatment needed
Treat symptomatically.
SECTION 5: Firefighting measures
5.1. Extinguishing media
Suitable extinguishing media
:
Sand. Water spray. Carbon dioxide. Dry powder. Foam.
Unsuitable extinguishing media
:
Do not use a heavy water stream.
5.2. Special hazards arising from the substance or mixture
Hazardous decomposition products in case of
fire
:
Carbon monoxide. Carbon dioxide.
5.3. Advice for firefighters
Firefighting instructions
:
Use water spray or fog for cooling exposed containers. Exercise caution when fighting any
chemical fire. Prevent fire fighting water from entering the environment.
Protection during firefighting
:
Do not attempt to take action without suitable protective equipment. Self-contained breathing
apparatus. Complete protective clothing.
SECTION 6: Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
6.1.1. For non-emergency personnel
Emergency procedures
:
Evacuate unnecessary personnel.
6.1.2. For emergency responders
Protective equipment
:
Do not attempt to take action without suitable protective equipment. For further information
refer to section 8: "Exposure controls/personal protection". Equip cleanup crew with proper
protection.
Emergency procedures
:
Ventilate area.
6.2. Environmental precautions
Avoid release to the environment. Notify authorities if product enters sewers or public waters.
6.3. Methods and material for containment and cleaning up
Methods for cleaning up
:
Take up liquid spill into absorbent material.
Other information
:
Dispose of materials or solid residues at an authorized site.
6.4. Reference to other sections
For further information refer to section 8 and 13.