957121_Optimag_082011:6 31.08.11 09:14 Seite 3 Contents EN Page Safety instructions Unpacking Correct use Operation Setting the operating mode Setting the safety temperature limit for Setting the temperature control mode for Assembling the stand Maintenance Error codes Technical data Accessories Warranty 3 5 5 5 6 6 6 7 7 8 9 10 10 Safety instructions For your protection • Read the operating instructions in full before starting up and follow the safety instructions.
3957121_Optimag_082011:6 31.08.11 09:14 Seite 4 For protection of the equipment • The appliance may only be opened by experts. • The voltage stated on the type plate must correspond to the mains voltage. • Do not cover the device, even partially e.g. with metallic plates or film. This results in overheating. • Ensure that the base plate is kept clean. • Protect the appliance and accessories from bumps and impacts.
3957121_Optimag_082011:6 31.08.
3957121_Optimag_082011:6 31.08.11 09:14 Seite 6 Setting the safe temperature limit Setting operating mode Operating the device in mode A or B Mode A All settings will be stored if the device is switched off or disconnected from the power supply. The agitation and heating functions will be set to OFF when the device is powered on. Mode B All settings will be stored if the device is switched off or disconnected from the power supply.
3957121_Optimag_082011:6 31.08.11 09:14 Seite 7 Changing the temperature control mode 1. Set target temperature to 2 °C 2. Switch off device 3. Hold down Heat/temp knob 4. Switch on device This activates or deactivates the two-point controller (2P) for the external PT 1000 temperature sensor (2P appears on the display). When switching on the device, 2P is also displayed next to the operating mode A/B when the two-point controller is activated.
3957121_Optimag_082011:6 31.08.11 09:14 Seite 8 Error codes Any malfunctions during operation will be identified by an error message on the display (E and F).
3957121_Optimag_082011:6 31.08.11 09:14 Seite 9 Technical Data Device Operating voltage range Vac 115+ 10% Nominal voltage Vac 115/ 60 Hz Frequency Hz 60 Power consumption (+10%) max. at 115 Vac W 610 Display Permissible duration of operation Permissible ambient temperature Permissible relative humidity Protection type acc.
3957121_Optimag_082011:6 31.08.11 09:14 Seite 10 Accessories • RS 1 • RSE • H 15 • H 28 • H 29 • H 30 • H 16 V • H 16.1 • H 38 • H 44 • ETS-D5 • ETS-D6 10 Warranty ø 10 mm, length upto 80 mm Set of magnetic stirring bars Stirring bar remover Bath attachment Bath attachment Oil bath attachment Oil bath attachment Support rod Extension Holding rod Cross sleeve Contact thermometer Contact thermometer In accordance with Chemglass warranty conditions, the warranty period is 24 months.