User Manual
User manual_CG920FGS 28/11/2012
OPTIONAL DUCTING ACCESSORIES
Changing the light bulb
Ensure the appliance is switched off before carrying out
maintenance, to avoid any possibility of electric shock.
Remove grease filter to relace lamp. Replace with 50W
(maximum) GU10 halogen lamps.
Charcoal filter
• Thecharcoalfiltershouldonlybeusedifyouwanttouse
the hood in the recirculation function.
• Thisfiltercannotbecleanedorre-usedandasageneral
rule, the activated charcoal filter should be changed once
every four months.
Fitting the charcoal filter
Fit one charcoal filter on the left and one on the right so as
to cover the plastic grids that protect the fan wheel.
• Always specify the hood model code number and
serial number when ordering replacement filters. This
information is shown on the registration plate located on
the inside of this unit.
• Replacement charcoal filters can be ordered from your
local Service Centre.
TROUBLESHOOTING GUIDE
PROBLEM REMEDY
The cooker hood will not start
Check that the hood is connected to an electrical supply
Check that a fan speed has been selected
The cooker hood is not working
Check that the fan speed is set high enough for the task
The grease filters are clean
The kitchen is adequately vented to allow the entry of fresh air
If set up for recirculation, check that the charcoal filter is still effective
If set up for extraction, check that the ducting and outlets are not blocked
The cooker hood has switched off
during operation
The safety cut-out device has been tripped – turn off the hob and wait for the device to reset.
If the hood has been installed below the heights indicated in the installation instructions the
motor will cut out frequently which will damage the hood
MAINTAINING YOUR RANGEHOOD
AR125RC
AR125F
AR610CF
AR610RK
AR125B
AR1200FS
AR125WV
Part Numbers Description
AR125RC 120mm G/Bond Roof Cowl
AR125F 120mm G/Bond Flue 1200mm
AR125WV 120mm Wall Vent
AR125FD 120mm Flexi Duct
AR610RK Recirculating Kit
AR610CF Replacement carbon mat filter
AR1200FS Stainless steel exhaust cover extension 1200mm
9
10