Document No. 10071753 Rev. 02 Page 17 of 28
24V Power Input
Inside NEO: +24V = White Cable (this pole of the Orange Connector has the Black stripe)
NEO
side
From
PSU
The power connection is a "tool less" connector (only wire strippers/cutters are needed to prep the wire
leads, no screw driver is required).
If the provided connector fails during use, the FS Technician may install the DC power using a UL-
approved wire connector junction such as 2-Position terminal block (CKP P/N 7155630) or equivalent.
Insulated connectors with a locking lever are also common (approved for use so long as they meet
local/national code for low voltage wiring and have UL-approval).
4.7.4 Power Supply
The Power Supply is part of the system. See section 7.0 for all Power Supply Requirements
.
+24V DC
GND
GND
+24V DC