Statements
The
device(s) may only be used for the intended purpose designed by for the manufacturer.
Unauthorized changes and the use of spare parts and additional devices which have not been sold or
recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures
shall exclude any liability by the manufacturer.
The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the
device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the
manual or automatically set parameters for a device or for an incorrect application of a device.
Repairs may only be executed by the manufacturer.
Installation, operation, and maintenance procedures should only be carried out by qualified personnel.
Use of the device and its installation must be in accordance with national legal requirements and local
electrical codes.
When working on devices the valid safety regulations must be observed.
Before touching the device, the power supply must always be interrupted. Make sure that the device is
without voltage by measuring. The fading of an operation control (LED) is not an indicator for an
interrupted power supply or the device being out of voltage!
The installer or licensed electrician must follow all NEC and local codes.
In accordance with article 725 of the NEC, UL will permit a product to be Listed, where Class 2 wiring is
notched in the floor and secured in place by non-water based/ non-corrosive material. Cables shall be
installed in a neat and workman like manner as described in article 725.8. In addition, UL also requires the
following with respect to interpedestal and other wiring from the pedestal. a Not to be installed in Damp or
Wet Locations. For indoor use only. b Wires are not to be embedded in concrete. c Circuits shall be
installed so as to not damage the cable.
All wires routed in the floor per article 725 must be Class 2 and be UL Listed. UL Recognized AWM may
be employed, provided it is enclosed in Conduit of ENT.
Inter-pedestal wiring should not be directly installed in wet concrete.
Inter-pedestal wiring scenarios (either in-floor, in walls, or in ceiling) that meet this UL guidance are
presumed to satisfy UL / cUL Listing requirements.