Installation Guide Part 3
NGL FX Installation Manual Rev. *
47 of 84
6. Click Apply. Figure 27X*** shows the switch setting parameters under the Tuning tab.
Figure 25X*** Tuning Settings
7. Under the Band Tab, fill in the following parameters:
• Frequency Band: Set to the application required by the customer. For more
information about the choices, refer to ***"Application-Based Detection
Modes" section in this document.
• Edge Blanking: Set to 0-15.
• Master/Submaster: Set to "Master" for any Single-Aisle System. For Multi-
Aisle Systems, refer to the "Multi-Aisle Setup" section below for the appropriate
setting.
• Q Band Detection: Choose a setting based on the type of tags used by the
customer (Hard tag, 410, etc.).
• Threshold Adjust: Set to either 16 or 0.
8. Click on Apply. Figure 28X*** shows the Band tab parameters for NGL. ***
Figure 26X*** Band Settings