Installation Guide Part 3
NGL FX Installation Manual Rev. *
63 of 84
The Repeater setting is used when many submasters are connected to the same master or the
distances between submasters is great. After daisy chaining the sync from board to board the sync
signal level or rise time could be reduced. For these cases enabling the Repeater on a submaster
will regenerate the sync pulse instead of just passively passing it on to the next submaster.
Table 6: Master/Submaster Sync
Switch Setting Function
Master/Slave/Set
up
Master Transceiver runs using on-board sync
Submaster Transceiver runs using external sync
Repeater Transceiver runs using external sync and is re generated
maintain sync signal quality.
Q Band Detection
The Q Band Detection switch selects No 'Q', HT (Hard Tag), 310 or 410 Q ranges.
Selecting No disables Q qualification. Any desired combination of 410, 310 or HT may be
selected to enable detection of the respective tags.
Table 7: Q Band Detection Switch
Switch Setting Function
Q Band Detection
Selection
No Q No limited Q range
HT (Hard Tag) Allows detection of tags with Q range 110-400
310 Allows detection of tags with Q range 80-110
310/HT Allows detection of tags with Q range 80-400
410 Allows detection of tags with Q range 50-85
410/HT Allows detection of tags with Q range 50-400
310/410 Allows detection of tags with Q range 50-110
310/410/HT Allows detection of tags with Q range 50-400
Note:
Selecting NO 'Q' increases the chance of phantom alarms.
Threshold Adjust
The Threshold Adjust setting should be set for either 0 or 16. In some earlier versions of firmware
this feature was not available.
After setting the switches as desired, click Apply.