Installation Guide Part 3

NGL FX Installation Manual Rev. *
56 of 84
The list below details the options available. If using the feature, then select the checkbox.
Enable SAM: This option button allows SAM to be Enabled (checked) or Disabled
(unchecked).
Enable Sweeper Immunity: Select this option if a sweeper is nearby and affecting the
board's detection. During installation leave this option off until the system is tuned so that
that DMS A view will accurately show any interfering noise characteristics. Once the
system has been tuned, this option can be set.
Enable Noise Immunity: Select this option if there is Environmental noise causing false
alarms. This option will decrease the sensitivity of the system in order to reduce the false
alarms.
Note:
To enable an item, check the box before it. Only checked items will be set when Apply is clicked.
22. Click the Options box (see Figure 35 Sam Screen). Click Option 00 to enable SAM.
Then, if the environmental conditions require, select options 08 or 09. Refer to Chapter 7:
NGL Tuning in order to determine if either or both of these options should be selected.
Once the required options have been chosen and enabled, click Apply.
A prompt appears that confirms that the smart alarm parameters were successfully set.
Click OK; this completes the configuration of this portion of SAM.
Changing the Patterns
The second tab within the SAM screen is the Patterns tab. This is where all possible types of alarm
signals get configured.
23. To enable patterns, click Alarm Patterns (see Figure 36: Alarm Patterns Enabled). This
activates the five components that need to be configured to create and/or update custom
alarm events. They are:
Alarm: choose from light or sounder alarms.
Priority: choose from a high or low priority signal.
Beep Pattern: choose from a short, medium, long, steady, quick, very short, 2-beep,
3-beep, 4-beep, silent, *L (one short beep, one long beep), **L (two short beeps and
one long beep) beep pattern.
Duration: choose how long (in seconds) the alarm either lights or sounds for each
alarm event.
Intensity: select the intensity (volume - sound) of an alarm event.
Note:
IIf the alarm duration is set to 31, the pedestal will alarm continuously.