Installation Guide Part 1
NGL FX Installation Manual Rev. *
26 of 84
Figure X***27: Unshielded Floor Trench Specifications
Mounting the Electronics Enclosure
Instructions for locating the Electronics Enclosure are included below.
It is important that the electronics enclosure be located no further than 12.2 linear-meters
[40 linear-feet] from the antenna panels to allow for bends in the 15.2 cable meters [50 cable feet]
run. The enclosure, which weighs 5.17kg [11.4lbs], has keyhole slots at its edges to facilitate
mounting to the wall surface. The mounting hardware can support the weight of the unit. Do not
mount the electronics enclosure beneath potential water sources (e.g. a sprinkler or pipe).
The enclosure must have 2.5cm [1 in] clearance on all sides. It is suggested to locate the enclosure
directly over (or nearest to) the conduit’s end wire as possible, ensuring the cable length is kept to
a minimum. Limiting exposed cable prevents interference (but do not cut, see “Transmission
Line,” and “Wrapped Cable” section). Use schedule 40 PVC conduit (contractor supplied) or wire
run, such as Checkpoint approved Dek Duct, to route the cable.
Installation procedures are listed for each type of material on which the enclosure can be installed:
• Wood Surface,
• Drywall, and
• Concrete.