Installation Guide Part 1

NGL FX Installation Manual Rev. *
21 of 84
Shielded FX Antenna Floor Cuts
Installing the FX antenna panels in an existing store requires a trough to be cut in the floor. If the
site is under construction, it is easier to mold the system into the floor (explained above). These
floor cut diagrams include the details on the size of the trough cuts required for each configuration.
101.6cm [40in]
91cm
[36in]
FX Shielded Potted
Matching Board
(CKP P/N 7193007)
FLOOR TROUGH –
7.6 cm [3in] Deep
Trough must be smooth and level
Figure 5X***: FX Shielded w/Potted Matching Board for 0.9m [3ft] Opening
Figure 6X***: FX Shielded w/Potted Matching Board for 1.8m [6’] Opening
It is possible to create a wider system by combing either of the smaller two floor kits (Figures 3-1
and 3.2). For example, to cover a 2.7m [9’] mall opening, a 0.9m [3’] kit and a 1.8m [6’] kit would
be ordered. Figure 3-3 (on the following page) shows the required floor cuts when a single antenna
and double antenna are combined. Following that, two double antennas are installed side by side.