User's Manual

ILS Open Plus Exit Antenna Installation: Connecting the Alarm Kit to the Serial-to-Ethernet
Connect the LED Indicators
The optical alarm indicator, the Signal LED, is integrated into the upper frame section.
This means, when installing the antenna, the standard upper frame section is replaced by
the one having the signal indicator and the Signal LED is connected with the connection
cable.
Figure 1.11
LED Annunciator Connection
1
See “Disassemble the Gates” on page 1-7 for instructions on how to disassemble the
gate.
2 Once the top molding is removed, connect the pin to the LED connector. The brown
connector connects to the positive (+) terminal.
3 Ensure that the cable is properly connected to the serial-to-ethernet board as instructed
at “Connecting the Alarm Kit to the Serial-to-Ethernet Board” on page 1-12.
4 Reassemble the gate as instructed at “Install the Cover Plates” on page 1-16.