User`s guide
©Microcontroller-café & Checkpoint LAB M35160 ERASER/PROGRAMMER User’s Guide
13
If the file size more than 32 bytes, you'll see warning window (Figure 15),
what telling that first 32 bytes ONLY from the file will copy into the incremental
area of the target M35080/M35160 memory.
Numeric display message
“ ri“ - read incremental registers:
Numeric display message
“ Li“ - write incremental registers:
4.5 ERASE : AU mode
Practical steps:
1. Re-mount mode jumper to “ AU“ position (Figure 2)
2. Make sure that “Function” jumper mounted to 160 or 080 position
NOTE: 160 position:M35080; D160D0WQ; D080D0WQ devices
080 position: M35080-3; M35080-6 devices
3. Turn ON the M35160 Eraser/Programmer, insert jack plug into power jack
4. Install the target device into the target socket (M35160 marked)
Notice: 1-pin on the target socked and programming adapter "◙" marked,
which point towards pin 1 of the device (Figure 3)
5. Make sure that numeric display message matches to this one:
“ AU“
Figure 16
Status message -->
Status message -->
Step 6
Press RS button
Press WR button
Function jumper
Step 2
Step 7