3.0 OPERATING PROCEDURES
3.1 Mounting Arrangements
TS2 Series sensors can be mounted in different ways:
M3 Screws
M4 Screws
3.2 Connector Assignment
NOTE: To assure immunity to random noise, the measuring head must be installed
be connected to the metal housing of the connecting plug.
Pin assignment viewed from outside:
1 - Vcc + 15 to 24 V DC regulated
2 - Ground
3 - Ground
4 - Signal output -
5 - Signal output +
1
3
Shield
2
5
4
Female socket M9
– 7 –
3.3 Options
Code DC Analog output 0 - 10 V DC
Code MA Analog output 4 - 20 mA
3.4 Initial Setup
of the 5-pin connector located on the rear side of the sensor is described in
section 3.2.
signicantly from the factory calibration material, you need to carry out
ZERO Adjustment and GAIN Adjustment as described in sections 4.1 and
4.2 before starting measurement.
the material path symbol on the front of the sensor.
1
2
3
4
5
Strand assignment of cable EK0620:
1 (white) Vcc + 15 to 24 V DC regulated
2 (black) Ground
3 (brown) Ground
4 (blue) Signal output –
5 (grey) Signal output +