User guide

– 8 –
No. Position of the
Selector Switch
(E)
Adjustable
Parameters
Description Display
(3) MENU PHASE deg:
0…359
Delay setting between the trigger signal
and ash (in degrees relative to the
frequency
Phase sift (PHASE in deg)
Phase shift setting (in degrees, relative to the frequency) between the trigger signal and ash. This value
allows a xed angle to be set between the trigger signal and ash.
• Example without external connection: The viewing position can be extremely precisely adjusted without
changing the ash frequency. You can shift the viewing position within a movement cycle.
• Example with external connection: The external trigger signal is triggered before the desired observation
point (= ash position of the stroboscope). This would mean that the connected stroboscope would
regularly ash too early. The PHASE deg setting adjusts the delay, altering the ash position of the
stroboscope by a set angle. This setting is not affected by the current rotational speed, which means that
the stroboscope will ash at the desired position even during rotational speed uctuations or during the
start-up period.
How to select in the MENU
1. Turn the selector switch (E) to the MENU position.
2. Select which parameter (e.g. PHASE deg) you want to change by turning the rotary/push knob (D).
3. Push the rotary/push knob (D) to conrm a parameter selection. The number shown in the display will
begin to ash.
4. Select the desired value by turning the rotary/push knob (D.)
5. Conrm and exit selection by pushing the rotary/push knob (D).
The setting is now active.
NOTE: The display and adjustable value can be changed by turning the rotary/push knob (D).