Owner's manual

Product subject to change without notice.
DIMENSIONS
SUPPLY VOLTAGE
10 to 30 VDC
Polarity Protected
CURRENT REQUIREMENTS
45 milliamps (exclusive of load)
OUTPUT TRANSISTORS
(1) NPN and (1) PNP output transistors
Sensor outputs can sink or source up to 150 milliamps
(current limit)
All outputs are continuously short circuit protected
RESPONSE TIME
Light state response = 100 microseconds
Dark state response = 100 microseconds
LED LIGHT SOURCE
High intensity red LED
Pulse modulated
PUSH BUTTON CONTROL
Automatic set-up routines based on web opacity
One push button set-up
Simultaneously pushing both buttons inverts the output
SPECIFICATIONS
HYSTERESIS
Minimal hysteresis promotes the detection between the
backing material and the label depending on the settings
LIGHT IMMUNITY
Responds to sensor’s pulsed modulated light source …
immune to most ambient light
INDICATORS
Green LED flashes when Autoset™ routine is activated
and stays illuminated when Autoset™ is completed
Red LED illuminates when sensors output transistors
are “ON”.
Note: The status of the output transistors can be inverted
by pushing both buttons simultaneously
AMBIENT TEMPERATURE
–40°C to 70°C (-40°F to 158°F)
RUGGED CONSTRUCTION
Chemical resistance to harsh cleaners such as
detergents, alcohols, and ketones
Waterproof, ratings: NEMA 2
Conforms to heavy industry grade CE and UL requirements
Model Numbers:
Label•Eye Description
LER Red LED, 4 conductor 6 ft. cable
LERC Red LED, 4-pin Nano connector
P/N Length Thread Coupling
GEC-6 6 ft. (1.8m) Straight Female
GEC-15 15 ft. (4.6m) Straight Female
RGEC-6 6 ft. (1.8m) 90° Female
RGEC-15 15 ft. (4.6m) 90° Female
Nano Cable (M8) Selection Guide
CHECK
LINE
®
–PRECISION QUALITY CONTROL INSTRUMENTS
Electromatic Equipment Co., Inc.
600 Oakland Ave.
Cedarhurst, N Y 11516 —USA
Tel: (800) 645-4330 (USA & Canada)
Tel: (516) 295-4300
Fax: (516) 295-4399
Email: info@checkline.com
Website: www.checkline.com