User guide
6
Factory Settings
The following charts reflect the default parameter and function settings as programmed by the factory:
Operating Mode -01- (RPM or Rate Measurement)
Panel Installation
Install the DT-5TXR/DT-5TS on panel as follows:
1. Confirm that the panel thickness is 0.047” - 0.197” (1.2 mm - 5 mm).
2. Remove the two mounting adapters (provided) from the DT-5TXR/DT-5TS (diagram 2).
3. Install a water-resistant gasket on the panel (see diagram 3 & 4).
4. Hold the panel meter in a horizontal position, insert it into the cut-out and press against gasket (diagram 5).
5. Replace the two mounting adapters (diagram 6).
6. The DT-5TXR/DT-5TS is secured on the panel by using the two mounting screws (provided) (see diagram 7).
3 margaid2 margaid
7 margaid6 margaid5 margaid
diagram 4
DISPLAY
1 Pulses
p
er revolution
_ _
0001 1
pp
r
2 Sensing RPM _ 01000 1,000 RPM
3 Display units 1000 1,000
4 Update time _ 1.0 _ 1 second
5 Display “Hold” after input signal ceases
_ _
006.0
6 seconds
6 In
p
ut filter
_
10
_
10 kHz
DEFAULT FACTORY SETTING
PARAMETER DESCRIPTION
DISPLAY
MEANING
1 The 2nd HI and 2nd LO limit setting 0 0 0 0 0 0 0
2 Hysteresis of 1st HI and 1st LO set _ _ _ _ 0 0 0
3 Secures the 1st HI and 1st LO set
_
0
_
Not secured
4 Out
p
ut activation of an
y
set limit
_ _ _ _
0 0 0 seconds
5 Selection of secondar
y
dis
p
la
y
_
0
_
1st HI and 1st LO limit set
6 Main display shows 0 below this no. setting 0 0 0 0 0 0 0
7 Averages the sensor output frequency _ 0 _ None
8 Deceleration to ZERO display value
_ 0 _
Off
10 Logic of BCD output _ 0 _ Negative-true logic
11 Analog output value 0 0 1 0 0 0. 1000
12 Minimum value of analog output 0 0 0 0 1 0. 10
13 Update time for analog output
_
0
_
About 10 msec
14 Offset for analo
g
out
p
ut
_
0 0 0.0 0%
DEFAULT FACTORY SETTING
Output modules (DT-5TXR only)
FUNCTION
DESCRIPTION
MEANING