Technical data

Hardware Health Monitoring
Check Point VSX Administration Guide NGX R67 | 165
UTM-1 130
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.1.1.3.1.0 > 80 20 "M/B Temp is too high"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.1.1.3.2.0 > 90 20 "CPU Temp is too high"
UTM-1 270
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.1.1.3.1.0 > 80 20 "M/B Temp is too high"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.1.1.3.2.0 > 100 20 "CPU Temp is too high"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.2.1.3.1.0 < 16320 20 "Case Fan speed is too
low"
UTM-1 570 and UTM-1 1070
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.1.1.3.1.0 > 80 20 "M/B Temp is too high"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.1.1.3.2.0 > 100 20 "CPU Temp is too high"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.2.1.3.1.0 < 4220 20 "CPU Fan speed is too low"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.2.1.3.2.0 < 16320 20 "Case Fan speed is too
low"
UTM-1 2070 and UTM-1 3070
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.1.1.3.1.0 > 80 20 "M/B Temp is too high"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.1.1.3.2.0 > 100 20 "CPU Temp is too high"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.2.1.3.1.0 < 4220 20 "Case Fan speed is too low"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.2.1.3.2.0 < 16320 20 "CPU 1 Fan speed is too low"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.2.1.3.3.0 < 16320 20 "CPU 2 Fan speed is too low"
Power-1 5070
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.1.1.3.1.0 > 80 20 "M/B Temp is too high"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.1.1.3.2.0 > 100 20 "CPU Temp is too high"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.2.1.3.1.0 < 4220 20 "Case Fan speed is too low"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.2.1.3.2.0 < 16320 20 "CPU 1 Fan speed is too
low"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.2.1.3.3.0 < 16320 20 "CPU 2 Fan speed is too
low"
Power-1 9070
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.1.1.3.1.0 > 100 20 "CPU 1 Temp is too high"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.1.1.3.2.0 > 100 20 "CPU 2 Temp is too high"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.1.1.3.3.0 > 80 20 "M/B Temp is too high"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.2.1.3.1.0 < 3000 20 "CPU 1 Fan speed is too
low"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.2.1.3.2.0 < 3000 20 "CPU 2 Fan speed is too
low"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.2.1.3.3.0 < 3000 20 "Case Fan speed is too low"
Power-1 11000
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.1.1.3.1.0 > 100 20 "CPU 1 Temp is too high"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.1.1.3.2.0 > 80 20 "M/B Temp is too high"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.1.1.3.3.0 > 100 20 "CPU 2 Temp is too high"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.2.1.3.1.0 < 0 20 "Case Fan 1 speed is too low"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.2.1.3.2.0 < 500 20 "CPU 1 Fan speed is too low"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.2.1.3.3.0 < 500 20 "CPU 2 Fan speed is too low"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.2.1.3.4.0 < 0 20 "Case Fan 2 speed is too low"
cp_monitor 1.3.6.1.4.1.2620.1.6.7.8.2.1.3.5.0 < 0 20 "Case Fan 3 speed is too low"