Technical data

Hardware Health Monitoring
Check Point VSX Administration Guide NGX R67 | 163
Physical Disks information
OID
Comment
Revision
.7
Size
.8
Maximum supported LBA
(Logical Block Addressing)
State
.9
One of the following:
ONLINE
MISSING
NOT_COMPATIBLE
FAILED
INITIALIZING
OFFLINE_REQUESTED
FAILED_REQUESTED
OTHER_OFFLINE
Flags
.10
One of:
OUT_OF_SYNC
QUIESCED
Sync state
.11
A percentage. Shows how much of the
backup disk is synchronized with the
primary disk
Example RAID Monitoring OIDs
OID
Meaning
1.3.6.1.4.1.2620.1.6.7.7.1.1.3.1.0
RAID type field of entry #1 from the volumes
table
1.3.6.1.4.1.2620.1.6.7.7.1.1.4.1.0
Number of disks field of entry #1 from the
volumes table
1.3.6.1.4.1.2620.1.6.7.7.2.1.4.2.0
Disk number field of entry #2 from the disks
table
SNMP monitoring rules are defined in the snmpd.conf configuration file. For full details see SNMP
Monitoring.
Sensors Monitoring with SNMP on VSX-1 Appliances
Note - The information in this section is taken from SecureKnowledge
solution sk42426
('http://supportcontent.checkpoint.com/solutions?id=sk2426)
On Power-1 and UTM-1 appliances the hardware status can be monitored using WebUI and SNMP polling,
or by defining the SNMP trap using the cp_monitor mechanism.
SNMP monitoring rules are defined in the snmpd.conf configuration file. For full details see SNMP
Monitoring. Examples of cp_monitor for various appliance types are as follows: